3 operating procedures, 2 ir illuminator controls, 1 operating the cipher – Armasight DACCIPHBB01NTS1 Cipher Digital Night Vision Clip-on System User Manual

Page 31

Advertising
background image

31

3.2.2 IR ILLUMINATOR CONTROLS

The controls of the optional IR illuminators are shown in Figure 3-21 and defined in Table 3-3. The ITEM

NO. column indicates the number used to identify items in Figure 3-14.

1

2

FIGURE 3-21. IR ILLUMINATOR CONTROLS

TABLE 3-3. IR ILLUMINATOR CONTROLS

ITEM NO.

FUNCTION

DESCRIPTION

1

POWER SWITCH

Switches the IR illuminator on/off and adjusts for radiated power.
Four ON-positions are located between two OFF positions, and are
each marked with a different-sized spot. The larger the spot, the
greater the radiated power.

2

LENS FOCUS

Adjusts for IR beam divergence. Adjustment range is covered with
approximately one turn of the lens.

3.3 OPERATING PROCEDURES

3.3.1 OPERATING THE CIPHER

WARNING:

When installing the equipment on a weapon, verify that the weapon is clear and that the safety

is on before proceeding.

CAUTION:

DO NOT force the equipment controls past their stopping points.

CAUTION:

Although the Cipher is highly resistant to damage from light overload, DO NOT point it, either

powered or inoperative, directly at the sun or any other source of high-intensity light that the

unprotected human eye cannot tolerate (such as welding arc). To prevent inadvertent expo-

sure, never leave the equipment unsupervised with the objective lens cap removed.

Advertising