4.2 TROUBLESHOOTING

The purpose of troubleshooting is to identify the most frequently occurring equipment malfunctions,

their probable causes, and the corrective actions required to fix them.
Table 4-2 lists common malfunctions that may occur during the operation or maintenance of the Nyx-7

PRO. Perform the tests, inspections, and corrective actions in the order listed in the table.
This table does not list all of the malfunctions that may occur with your device, or all of the

tests and corrective actions that may be necessary. If you experience an equipment malfunction

that is not listed, or is not fixed by the corrective actions listed in the table, please contact Armasight’s

Customer Service center.

TABLE 4-2. OPERATOR TROUBLESHOOTING

MALFUNCTION

PROBABLE CAUSE/ TEST/INSPECTION

CORRECTIVE ACTION

Unit fails to activate.

Battery is dead, missing or improperly

installed.

Replace the battery or install it correctly.

Battery contact surfaces or contact

springs are dirty or corroded.

Clean the contact surfaces with a pencil eraser

and/ or alcohol and cotton swabs.

Defective image intensifier.

Please contact Customer Support.

IR illuminator fails to activate.

Turn the IR illuminator on in a dark area.

Visually estimate whether or not the ob-

served scene is illuminated.

If the IR illuminator fails to activate, please contact

Customer Support.

LED indicators fail to activate.

Visual inspection.

Please contact Customer Support.

Poor image quality.

Check objective lens or eyepiece focus.

Refocus the lens.

Check for fogging or dirt on the lens.

Clean the lens as detailed in Part 4.4.2 of this man-

ual. If image quality is still poor, please contact

Customer Support.

Damaged optical components.

Please contact Customer Support

Light is visible around the eye-

cup.

Check the exit pupil distance value.

Readjust for proper eye-relief distance.

Check the eyecup resilience.

If the eyecup is defective, please contact Cus-

tomer Support.

Focusing ring cannot be moved.

Check to see if the focusing ring is bent

or broken.

If damaged, please contact Customer Support.

Eyepiece ring cannot be moved.

Check to see if the eyepiece ring is bent

or broken.

If damaged, please contact Customer Support.

4.3 IDENTIFICATION OF OPERATIONAL DEFECTS

4.3.1 OPERATIONAL DEFECTS

Operational defects relate to the reliability of the intensifier, and are an indication of instability. If iden-

tified, the user will need to return the Nyx-7 PRO immediately. Operational defects include shading,

edge glow, flashing, flickering, and intermittent operation.

A. Shading

If shading is persistent, you will not be able to see a fully circular image (Figure 4-1). Shading is a very

dark, high-contrast area with a distinct line of demarcation present, and you cannot see an image

through it. Shading always begins on the edge, and will eventually migrate inward until it spans across

the entire image area. If you notice shading with your device, please contact Customer Support.