C2G 29404 Multifunction Cable Meter User Manual

Page 4

Advertising
background image

TONE SCREEN

Pressing the Tone function key in the Mode Screen presents the Tone Screen

and the CableTool begins transmitting the user selected tone pattern and frequency
(see Tone Setup).

The CableTool provides four different tone patterns which can be changed by

pressing the Up/Down cursor key. The tone
frequency can be changed by pressing the
Select function key to move the arrow to the
Band field and then pressing the Up/Down
cursor key to change the frequency band.

SETUP

Pressing the Setup function key in any screen presents the Setup Screen.

The Up/Down cursor key is used to display: 1) Units Setup 2) Default Cable

Setup 3) Cable List Setup 4) Custom Cable Setup 5) Toner Pattern/Band Setup and
6) Power Down Setup. Press the Select function key to enter the displayed setup
screen.

UNITS SETUP

The Units Setup Screen is used to select the units used when displaying the

length measurement in the Length screen.

The Up/Down cursor key is used to select
Feet or Meters. Press the Save function key to
store the selected units.

CABLE LIST SETUP

The CableTool has a prestored list of over 60 popular cable types with the

typical NVP value for each cable. Cable List setup allows the user to store the
most often used cable types at the top of the list for quick access and to modify
the typical NVP when the actual NVP is known to be different value.

Pressing the Up/Down cursor key scrolls

between the eight storage locations. Pressing
the Select function key advances the arrow to
the Type field where any one of the prestored
cable types can be displayed by pressing the

Up/Down cursor key. Pressing the Select function key again advances the arrow
to the NVP field which can be modified by pressing the Up/Down cursor key.
Press the Save function key to store the information.

DEFAULT CABLE SETUP

Default Cable setup allows the user to store the most often used cable type

as the default for the Length measurement in the Length screen. The Default Cable
is used when the Length function is selected and length measurements begin.

Pressing the Up/Down cursor key scrolls

between the eight storage locations. Press the
Save function key to select the displayed cable
as the Default for length measurements.

CUSTOM CABLE SETUP

Custom Cable Setup is used to measure and store the NVP of a cable of a

known length. Connect the CableTool to a piece of cable that is between 50 and
100 feet long and is open at the far end. Cables less than 50 feet or longer than
100 feet may not give accurate NVP results.

Press the Up/Down cursor key to select one of

the four Custom Cable storage locations. Press
the Select function key to advance the arrow to
the length field and then use the Up/Down
cursor key to adjust the displayed cable length

until it matches the known length. The NVP changes as the displayed cable length
is adjusted. Press the Save function key to store the information.

TONER SETUP

The CableTool has four different tone patterns and four different tone

frequencies that can be used to trace a cable with a tone probe. The frequencies
and patterns are compatible with tone probes from different manufacturers. The
different patterns and frequencies allow multiple technicians to be working in the
same area and still be able to uniquely identify the cable being traced.

Pressing the Up/Down cursor key scrolls

between the four transmitted patterns. Pressing
the Select function key advances the arrow to
the Band field where one of four frequencies can
be selected.

Press the Save function key to store the displayed Pattern and Band as the Default
for Toning.

Advertising