Camp Chef MS2GG User Manual

Page 3

Advertising
background image

1. DO NOT leave this appliance unattended

while in use. The user must remain in the
immediate area of the product and have a
clear view of the product at all times during
operation.

2. Keep children and pets away from burner

at all times.

3. The use of alcohol, prescription or non-

prescription drugs may impair your ability
to properly assemble or safely operate this
appliance.

4. For OUTDOOR use only. Do NOT use in a

building, garage or any other enclosed
area. Do NOT use in or on recreational
vehicles or boats. NEVER use this appliance
as a heater.

5. Do not operate appliance under ANY

overhead construction. Keep a minimum
clearance of 1 foot (0.3 m) from the
sides, front and back of appliance to
ANY construction. Keep the area clear of
all combustible material and flammable
liquids, including wood, dry plants and
grass, brush, paper, and canvas. Never use
this appliance within 25 ft. (7.5 m) of
any flammable liquid.

6. Use ONLY on a level, stable surface.
7. DO NOT place an empty cooking vessel

on burner while in operation. Use caution
when placing anything in the cooking
vessel while burner is in operation.

8. Do NOT move the appliance when in use.

Allow unit to cool to 115°F (45°C) before
moving or storing.

9. This appliance will be hot during and after

use. Use insulated oven mitts or gloves for
protection from hot surfaces or splatter
from cooking liquids.

10. In case there is a fire, call the local fire

department or dial 911. Stay clear from
flames. Do not attempt to extinguish an
oil or grease fire with water.

11. Do not obstruct the flow of combustion

and ventilation air.

NOTE: This appliance is set to use 16.4 oz.
disposable propane cylinders. Use only cylinders
marked propane. Disposable propane cylinders
must be disconnected from the stove when it is in
storage.
Refillable Bulk LP-Gas Tanks with a maximum
capacity of 20 pounds may also be used with an
optional bulk tank adapter hose. (Use Camp
Chef Model HRDSP to connect to the bulk tank.)
Refillable propane gas cylinders must be turned off
at the LP-Gas supply cylinder when the stove is not
in use.
The LP-gas cylinder(s) used with this stove must
be constructed and marked in accordance with
the specifications for LP-gas cylinders of the U.S.
Department of Transportation or Transport Canada,
CAN/CSA B339.

Setup Using Disposable Bottle
1. Make sure burner valves are off.
2. Remove plastic cap from top of propane

cylinder. Save cap for use in storing. Screw
propane cylinder into regulator. Be careful
not to cross thread. Hand Tighten only.

3. Check the connection between the cylinder

and the regulator with soapy water.
Bubbles indicate a leak. Check that the
connection is not cross-threaded and that
it is tight. Perform another leak check. If
there is still a leak, remove the cylinder and
contact the manufacturer for service or
repair.

4. The regulator uses a threaded fitting to

attach to the stove. It is necessary to hold
the stove to make sure the fitting is seated.
Align the regulator to the fuel tube on the
rear of the stove and push on. Screw on
the outer threaded sleeve in a clockwise
direction until tight.

5. Never operate stove with propane cylinder

in an inverted position.

Setup Using Optional Hose And Refillable
Cylinder
1. Make sure burner valves are off.
2. Attach Camp Chef Model HRDSP hose to

regulator & regulator to stove (as shown).

3. Attach hose to cylinder.
4. Open cylinder valve.
5. Perform leak check on hose to regulator,

and hose to cylinder connections with soapy
water. Bubbles indicate a leak. Check that
the connection is not cross-threaded and
that it is tight. Perform another leak check.
If there is still a leak, remove the cylinder
and contact the manufacturer for service
and repair.

6. Turn off fuel at the cylinder and disconnect

both ends of the hose when not in use.

Dismantling Hose And Refillable Cylinder
1. Before dismantling high pressure hose, be

sure gas pressure in hose is eliminated.

2. Ignite stove and turn off gas valve on

cylinder.

3. Allow flame to self-extinguish.
4. When flame is out, close valves on the

appliance.

5. Remove hose.

Installation Safety Precautions
• Use appliance only with LP (propane) gas

and the regulator/valve assembly supplied.

• Appliance is not for use in or on
recreational vehicle and/or boats.
• Do not modify this appliance. Modifications

will result in a safety hazard. Questions
regarding certification in other areas may be
addressed to 1-435-752-3922.

• Apartment Dwellers: Check with

management to learn the requirements and
fire codes for using an LP Gas appliance at
an apartment. If allowed, use outside on the
ground floor with a 10 foot clearance from
walls or rails.

• Before opening LP tank valve, check the

coupling nut for tightness. When appliance
is not in use, turn off control knob and LP

tank valve on supply cylinder.

• Never use LP tank if visibly rusted, damaged,

or out of date.

• If you notice grease or other hot material

dripping from appliance onto valve, hose
or regulator, turn off gas supply at once.
Determine the cause, correct, clean and
inspect valve, hose and regulator before
continuing. Perform a leak test.

• The regulator may make a humming or

whistling noise during operation. This will
not affect the safety or use of appliance.

• Clean and inspect the hose before each

use of the appliance. If there is evidence of
abrasion, wear, cuts or leaks, the hose must
be replaced prior to the appliance being put
into operation. See product tag for hose &
regulator information.

• Do not block holes in bottom or sides of

appliance.

• Never operate appliance with LP tanks out

of correct position specified in Assembly
Instructions.

• Always close LP tank valve and remove

coupling nut before moving LP tank form
specified operating position.

• NEVER store a spare LP tank under or near

appliance or in enclosed areas. NEVER fill
the cylinder beyond 80% full. An overfilled
spare LP tank is hazardous due to possible
gas released from the safety relief valve.
Failure to follow these instructions exactly
could cause a fire resulting in death or
serious injury.

• If you see, smell, or hear escaping gas,

immediately get away from the LP tank/
appliance and call your fire department.

• All spare LP tanks must have safety caps

installed on the LP tank outlet.

Leak Test

Leak Check

Regulator
& Hose

WARNING

Combustion by-products produced
when using this product contain
chemicals known to the State of
California to cause cancer, birth
defects, or other reproductive harm.

WARNING

24 “

Hose is a trip hazard

Advertising