Bat40vc, Maximum ratings, Thermal characteristics – Diodes BAT40VC User Manual

Page 2: Electrical characteristics

Advertising
background image

BAT40VC

Document number: DS30637 Rev. 6 - 2

2 of 4

www.diodes.com

October 2010

© Diodes Incorporated

BAT40VC





Maximum Ratings

@T

A

= 25°C unless otherwise specified

Characteristic

Symbol

Value

Unit

Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage

V

RRM

V

RWM

V

R

40

V

Forward Continuous Current (Note 4)

I

F

200

mA

Repetitive Peak Forward Current (Note 4)

I

FRM

350

mA

Forward Surge Current (Note 4) @tp =10ms

I

FSM

750

mA




Thermal Characteristics

Characteristic

Symbol

Value

Unit

Power Dissipation (Note 4)

P

D

150

mW

Thermal Resistance, Junction to Ambient Air (Note 4)

R

θJA

833

°C/W

Operating and Storage Temperature Range

T

J

, T

STG

-65 to +125

°C




Electrical Characteristics

@T

A

= 25°C unless otherwise specified

Characteristic

Symbol

Min

Typ

Max

Unit

Test Condition

Reverse Breakdown Voltage (Note 5)

V

(BR)R

40

V

I

R

= 100

μA

Forward Voltage

V

F

330
420
800

1000

mV

I

F

= 2.0mA

I

F

= 15mA

I

F

= 100mA

I

F

= 200mA

Reverse Leakage Current (Note 5)

I

R

500

nA

V

R

= 25V

Total Capacitance

C

T

10

pF

V

R

= 1.0V, f = 1.0MHz

Reverse Recovery Time

t

rr

5.0

ns

I

F

= 10mA through I

R

= 10mA

to I

R

= 1.0mA, R

L

= 100

Ω

Notes:

4. Device mounted on FR-4 PCB, 1 inch x 0.85 inch x 0.062 inch; pad layout as shown on Diodes Inc. suggested pad layout document AP02001, which
can be found on our website at http://www.diodes.com/datasheets/ap02001.pdf. T

A

= 25°C.

5. Short duration pulse test used to minimize self-heating effect.


























Advertising