Recommended operating conditions – Diodes 74HCT594 User Manual

Page 4

Advertising
background image

74HCT594

Document number: DS35491 Rev. 2 - 2

4 of 12

www.diodes.com

June 2013

© Diodes Incorporated

74HCT594

Absolute Maximum Ratings

(Note 4) (@T

A

= +25°C, unless otherwise specified.

Symbol

Description

Rating

Unit

ESD HBM

Human Body Model ESD Protection

2

KV

ESD CDM

Charged Device Model ESD Protection

1

KV

ESD MM

Machine Model ESD Protection

200

V

V

CC

Supply Voltage Range

-0.5 to 7.0

V

V

I

Input Voltage Range

-0.5 to 7.0

V

V

o

Voltage applied to output in high or low state

-0.3 to V

CC

+0.5

V

I

IK

Input Clamp Current V

I

< -0.5V

-20 mA

I

IK

Input Clamp Current VI > V

cc

+0.5V

20 mA

I

OK

Output Clamp Current V

O

<-0.5V

-20 mA

I

OK

Output Clamp Current V

O

> V

CC

+ 0.5V

20 mA

I

O

Continuous output current

Q7 standard output

+/- 25

mA

Qn bus driver outputs

+/- 35

mA

I

CC

Continuous current through V

cc

70 mA

I

GND

Continuous current through GND

-70

mA

T

J

Operating Junction Temperature

-40 to +150

°C

T

STG

Storage Temperature

-65 to +150

°C

P

TOT

Total Power Dissipation

500

mW

Notes: 4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device

operation should be within recommend values.


Recommended Operating Conditions

(Note 5)

(@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Conditions

Min Max

Unit

V

CC

Supply

Voltage

4.5 5.5

V

V

I

Input

Voltage

0 5.5

V

V

O

Output Voltage

Active Mode

0

V

CC

V

t/V

Input transition rise or fall rate

V

CC

= 4.5V to 5.5V

500 ns/V

T

A

Operating free-air temperature

-40 +125

°C

Notes: 5. Unused inputs should be held at V

CC

or Ground.


Advertising