The PumpSaver

®

Plus Model 231-P-INSIDER fits inside 1/3 – 1hp, 230V Franklin™, Pentek™, or

CentriPro™ control boxes. PumpSavers are designed to protect single-phase pumps from dry-well,

dead-head, rapid-cycling, jammed impeller, and over/undervoltage conditions. Typical applications

include residential waterwells, commercial waterwells, irrigation wells, and golf course and other

sprinkler systems.

CONNECTIONS

Refer to specific connection instructions depending on the particular control box being used:

Franklin™

control

box

page

3

Pentek™

control

box

page

5

CentriPro™

control

box

page

7

CALIBRATION / SETTINGS

1. Turn RESTART DELAY/CALIBRATION to the CAL position and close the box cover.

2. Apply power to the system. The pump should run for approximately 10 seconds and then shut

off—this indicates the Model 231-P INSIDER has calibrated.

3. Remove power from the system. Open the control box and set the appropriate dry-well recovery

time with the RESTART DELAY / CALIBRATION knob.

4. Shut the control box and re-apply power to the system.

OPERATION

The Model 231-P-INSIDER monitors pump load in amps and kilowatts. When the current (amps)

exceeds approximately 125% of calibrated current, or power (kW) drops below the adjustable

underload trip point, the 231-P-INSIDER—after the trip delay—will turn off the pump. The 231-P-

INSIDER will automatically restart the pump after the selected restart delay time.

The calibration is stored in permanent memory. The PumpSaver

®

Plus does not need to be

recalibrated if power is lost.

SENSITIVITY

The Model 231-P-INSIDER has an adjustment knob to set the underload trip sensitivity. Setting
SENSITIVITY to the middle position (straight up) is equivalent to SymCom’s standard underload

trip level. Adjust the SENSITIVITY knob to increase/decrease underload sensitivity up to

approximately ±10% of the standard trip. It may be necessary to increase the sensitivity if the

PumpSaver

®

Plus does not trip on dry-run or dead-head or it is known that the water level in the

well is very low relative to the pumps capabilities.

WARNING: Decreasing the SENSITIVITY may compromise the PumpSaver’s ability to

detect dry-run and/or dead-head conditions.