SymCom PumpSaver

®

Plus Model 233-P protects 230V, 2 or 3-wire, 1/3 – 3hp, single-phase pumps

from dry-well, dead-head, rapid-cycle, jammed-impeller, overvoltage and undervoltage conditions.

Typical applications include submersible pumps, centrifugal pumps, circulating pumps, cooling

pumps, environmental pumps, residential waterwells, commercial waterwells, irrigation wells, and

golf course and other sprinkler systems.

DISCONNECT POWER PRIOR TO INSTALLATION!

FOLLOW NATIONAL, STATE AND LOCAL CODES!

CONNECTIONS

NOTE: Use in conjunction with UL listed or recognized thermal or solid-state overload

relays only.

1. Mount the PumpSaver

®

Plus Model 233-P in a convenient location in or near the pump control

box. If the location is wet or dusty, a NEMA 3R, 4, or 12 enclosure should be used.

2. Connect one line from the fused disconnect to the Model 233-P’s L1 IN terminal. Run a wire

from the L1 OUT terminal to the other in-line controls such as pressure or float switches.

3. Connect the other line from the fused disconnect to the Model 233-P’s L2 IN terminal. Run a

wire from the L2 OUT terminal to the other in-line controls such as pressure or float switches

(see Figure 1).

4. Refer to the appropriate wiring diagram for your specific application:

Typical wiring diagram – Figure 1

Standard 3-wire control box – Figure 2

Deluxe control box – Figure 3

2-Wire pump direct feed – Figure 4