Aquavar SOLO – Quick Installation Guide

1. Mount Aquavar SOLO Drive (in a vertical position);

• Must have 6” minimum clearance on all sides for proper cooling.

2. Wire Input Power to SOLO Drive (Single Phase, 230V)

• Review Circuit Breaker Sizing - see IMS-SOLOQ-2 or IM229

3. Wire Motor Drop Cable to SOLO Drive (75˚C Copper Wire min.)

• 3AS Models - Use with Three Phase, 230V, ¾ to 5 HP Motors
• 1AS15 Model - Compatible w/Single Phase, 230V Motors

3-Wire - .5 - 2 HP CP / Pentek XE; .5 – 1.5 HP FE & Grundfos

2-Wire - .5 – 1.5 CentriPro, Pentek XE, Franklin Elec. & Grundfos 2-Wire

– units with R05K or newer software only.

• Review Wire Sizing (Table 4 of IM229)

4. Mount Transducer and Confirm Transducer Cable Wiring

• Transducer cable maximum length = 200 feet
• Connect Pressure Transducer to piping manifold and to ground

5. User Interface Board Adjustments

• Select proper “Current Limit Setting” (equal to motor SFA)
• 1AS15 Only - Set “Pump Stop Sensitivity” - High is Default
• 3AS_ _ Only - Select maximum frequency setting (60 Hz or 80 Hz);

60 Hz = matching Liquid End HP and Motor HP

80 Hz = “over-speed” application; motor HP > Liquid End HP

• Dry Well Sensitivity - Set on “High” position;

If nuisance tripping occurs, switch to “Low” position

• Low Pressure Cut-Off and Pressure Drop setting adjusted to application /

system requirements.

• Optional use of Secondary Switch Connection, refer to IM229

6. Adjust Tank Pressure

• Set approximately 20 PSI below pressure set point
• Adjust as needed to optimize - see IMS-SOLOQ-2 or IM229

7. Turn Drive Power On - Adjust Pressure - Purge Air

• Purge air from system and check for leaks
• Factory default is 50 psi - push and hold Increase Pressure button if

higher pressure is desired and also adjust tank pre-charge.

8. Check Motor Rotation and Confirm Performance

Refer to Aquavar SOLO Installation Manual, IM229, for complete details.
Check Motor Insulation Resistance on retrofit jobs before replacing drive.