Xylem IM222 Ag-Flo Gasket Assembly Instructions User Manual

Goulds pumps, Ag-flo, Engineered for life

Advertising
background image

ITT

Goulds Pumps

Ag-Flo

Gasket Assembly Instructions

Ag./Irrigation

Goulds Pumps is a brand of ITT Corporation.

www.goulds.com

Engineered for life

IM222

The 1¼ x 1½ x 9½, 2 x 2½ x 7, 5 x 6 x 7 and 6 x 8 x 9½ pumps use a casing gasket instead of an

O-Ring to seal the pump casing.

Initial Gasket Installation (New Pump):

1. Inspect gasket to ensure that there are no creases or tears.

2. Inspect Motor adapter and Casing surfaces where gasket is to seal and ensure that surfaces

are clean.

3. Place gasket on motor adapter. It may be necessary to hold gasket in place with petroleum

jelly or gasket grease. Ensure the gasket is not creased and sets evenly on the motor adapter.

4. Place the casing on the motor bracket and tighten casing bolts.

Replacing the Casing Gasket:

1. Inspect gasket to ensure that there are no creases or tears.

2. Clean and scrap Motor adapter and Casing surfaces where gasket is to seal and ensure that

surfaces are clean, before the new gasket is installed.

3. Place gasket on motor adapter. It may be necessary to hold gasket in place with petroleum

jelly or gasket grease. Ensure the gasket is not creased and sets evenly on the motor adapter.

4. Place the casing on the motor adapter and tighten casing bolts.

Pump Model

22BF

24BF

25BF

26BF

1¼ x 1½ x 9½ 2 x 2½ x 7

5 x 6 x 7

6 x 8 x 9½

Pump

Size

Advertising