H-335 Operation 1-9
Figure 2 Installation Configurations
In practice the following steps must be done with two people. One working on the gate pier and the other on
the dam catwalk with a data logger or laptop computer connected to the SDI-12 bus. A hand held radio
makes it easier to communicate be between the two workers. During the installation procedure the
SensorAngle must be monitored in real time. Ignore the UserAngle value at this time. The offset adjustment
can be done in two ways: