Xylem Palmer & Bowlus flumes User Manual

Palmer & bowlus flumes, Installation instructions

Advertising
background image

Installation Instructions

MJK Automation A/S
Byageren 7
DK-2850 Nærum
Denmark
Tel.: (+45) 45 56 06 56
Fax: (+45) 45 56 06 46
[email protected]
www.mjk.dk

MPBGB0204

As our products are developed continuously,
we reserve the right to make any changes without prior notice.

Palmer & Bowlus flumes

It is very important for the overall measuring
accuracy to comply with the installation
instructions on the next page.

The Palmer & Bowlus flume is characterized
by its circular connection which makes it
easy to install in pipelines.

The flume is aimed at measurement in the
scale of 20 - 100 % of the nominal flow.

No simple formula can be set up for the
Palmer & Bowlus flumes; the formulas are
defined individually for every flume.

General

Flume sizes

Size:

Q

min

Q

max

F

H

Ha

Weight

8”

DN 200 (

200 mm)

14 m

3

/h

70 m

3

/h

100 mm

See note

151 mm

2.8 kg

10” DN 250 (

250 mm)

22 m

3

/h

110 m

3

/h

125 mm

below.

179 mm

3.5 kg

12” DN 315 (

315 mm)

40 m

3

/h

200 m

3

/h

150 mm

240 mm

4.8 kg

15” DN 400 (

400 mm)

65 m

3

/h

325 m

3

/h

200 mm

277 mm

9.8 kg

24” DN 600 (

600 mm)

220 m

3

/h

1100 m

3

/h

300 mm

453 mm

15.6 kg

30” DN 800 (

800 mm)

330 m

3

/h

1750 m

3

/h

400 mm

540 mm

30.1 kg

Material:

8”, 10”, 12”:

Glass fibre reinforced polyester / PVC

15”, 24”, 30”: PVC

pH range:

pH 3 - 10

Temperature range:

- 20 … +30 °C, for short periods up to 90 °C

Note: Max. height H must never exceed the measuring range for the flowmeter + deadband.

Note!

For the Palmer & Bowlus flumes with the
dimensions as listed in the table below, the
flow formulas are defined and incorporated
in the flow converter and is chosen in the
menu “Programming of flow calculation”.