Measuring distances for Palmer & Bowlus flumes
















Diameter D: Distance L:

Diameter D: Distance L:

4”

2”

18”

9”

6”

3”

21”

10.5”

8”

4”

24”

12”

10”

5”

27”

13.5”

12”

6”

30”

15”

15”

7”

Measuring distances for rectangular weirs
- with and without side contraction













the distance l should be between 4 to 5 times the nomi-
nal width b.

Measuring distances for V-notch weirs

the distance l should be between 3 to 4 times the
height h of the notch.

4: Mount the sensor in the correct upstream distance

from the head in the flume / weir.
the distance depends on the dimension and type
of flume / weir.

Measuring distances for Parshall flumes

















Throat width b: Distance L:

Throat width b: Distance L:

1”

10”

36”

43”

2”

11”

48”

47”

3”

12”

60”

51”

6”

16”

72”

56”

9”

23”

84”

59”

12”

36”

96”

63”

18”

37.5”

120”

72”

24”

39”

144”

80”

(L = D/2)