John Wood Power Direct Vent (ENERGY STAR) User Manual

Page 25

Advertising
background image

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Error 7

The self-diagnostic test found
a problem with the gas valve
driver circuit.

1. Cycle power to the water heater “OFF” for 10 seconds and then

back “ON”.

2. If the above step did not clear the error, the control must be

replaced.

Error 8

The self-diagnostic test has
detected a problem with the
internal microcomputer.

1. Cycle the external power “OFF” for 10 seconds and then back

“ON”.

2. If the above step does not clear the error, the control must be

replaced

Error 9

The self-diagnostic test has
detected a problem with the
internal circuit.

1. Cycle the external power “OFF” for 10 seconds and then back

“ON”.

2. If the above step does not clear the error, the control must be

replaced.

Error 10

Flame signal sensed out of
proper sequence.

1. Ensure flame sensor ceramic insulator is not cracked.
2. Turn power off for 10-20 seconds, and then on again to clear the

error code.

3. Replace the control.

Error 11

The high temperature
thermal cutoff is open.

1. Turn the power off for 10-20 seconds then on again to clear the

error code.

2. Replace the control.

Error 12

The self-diagnostic test
has detected one of the
temperature adjust buttons
stuck closed.

1. Make sure that there are no objects leaning against the front of

the control.

2. Lightly press and release each of the buttons once.
3. If the above actions do not clear the error, the control will continue

to regulate water temperature at the last setting, but you will not
be able to change settings unless you replace the control.

Error 13

The self-diagnostic test
has detected that the water
temperature sensor is either
open or short circuited.

1. Turn the power off for 10-20 seconds then on again to clear this

error code.

2. If no wiring problems are found the control must be replaced.

Table 5. Intelli-Vent

TM

System Error Codes.

– 25 –

Advertising