BBG 6 A • Connections, Indicators, and Controls

Connections, Indicators, and Controls

BBG 6 A •

Specifications, Parts, and Accessories





e

Audio output connector Insert a 3.5 mm, 5-pole captive

screw connector into this connector for a balanced or

unbalanced 1 kHz sine wave audio tone.

N

Do not tin the stripped power supply leads before

installing the captive screw connector. Tinned wires are

not as secure in the captive screw connectors and could

pull out.

CAUTION

For unbalanced audio, connect the sleeve(s) to the ground contact.

DO NOT

connect the sleeve(s) to the negative (-) contacts.

Unbalanced Output

Balanced Output

Tip

Sleeve (s)

Tip

Tip

Ring

Sleeve (s)

Tip

Ring

NO Ground Here

NO Ground Here

3/16" (5 mm) MAX.

Figure 6 — BBG 6 audio wiring

f

Power connector Plug the external 12 V power supply

into this 2-pole captive screw connector. The power supply

is included with the unit. Figure 7 shows how to wire the

connector.

C

When connecting the power supply, voltage polarity

is extremely important. Applying power with

incorrect voltage polarity could damage the power

supply and the BBG 6 A. Identify the power cord

negative lead by the ridges on the side of the cord or

the black heat shrink wrapping around it.

Power Supply

Output Cord

Captive Screw

Connector

A

A

SECTION A–A

12 V

3/16” (5 mm) MAX.

+

+

-

-

Figure 7 — Power connector wiring

N

Do not tin the stripped power supply leads before

installing the captive screw connector. Tinned wires are

not as secure in the captive screw connectors and could

pull out.

W

The two power cord wires must be kept separate

while the power supply is plugged in. Remove

power before continuing.

To verify the polarity before connection, plug in the power

supply with no load and check the output with a voltmeter.
As an alternative, you can use an Extron P/S 100 Universal

12 VDC Power Supply (part #60-357-01), which can power up to

ten BBG 6 As or other Extron 12 VDC devices using only one AC

power connector.

g

Version label — Differentiates the standard (NTSC and PAL

signals) versus Japanese (BBG 6 A J, NTSC signals only) versions

of the BBG 6 A.

Specifications

Blackburst output

Number/signal type ..................... 6 blackburst (two can be switched to

color bars)

Connectors ..................................... 6 BNC female
Standards

BBG 6 A ............................... RS-170A standard for NTSC 3.58,

CCIR 624-4 standard for PAL

BBG 6 A J............................. RS-170A standard for NTSC 3.58

Impedance ..................................... 75 ohms
Sync level

BBG 6 A ............................... 40 IRE for NTSC, 43 IRE for PAL
BBG 6 A J............................. 40 IRE for NTSC

Color burst level

BBG 6 A ............................... 40 IRE for NTSC, 43 IRE for PAL
BBG 6 A J............................. 40 IRE for NTSC

Setup level

BBG 6 A ............................... 7.5 IRE (NTSC) or 0 IRE (PAL)
BBG 6 A J............................. 0 IRE (NTSC)

Tolerance for all levels .................. ±3%
Subcarrier levels

BBG 6 A ............................... NTSC 3.579545 ±3 Hz

PAL 4.433618 ±3 Hz

BBG 6 A J............................. NTSC 3.579545 ±3 Hz