AVT 200HD Tuner • Remote Configuration and Control

62

Command

ASCII Command

(Host to Tuner)

Response

(Tuner to Host)

Additional Description

IP Setup Commands (continued)
View broadcast mode

E

EB

}

Bmd

X9%

,

X5$]

Set broadcast port and MAC
address

EX4@

*

X10#

*

X10$

PB

}

Bpt

X4@

*

X5(]

X4@

= UDP outgoing port

X10#

*

X10$

= MAC address for

UDP unicast transmissions

Set event target IP address

EX7$

,

X5$

ID

}

Edi

X7$

*

X5$

*

X4@]

X7$

= event number (event must

be running).

X7$

= 0–99.

Set event target TCP port

EX7$

,

X4@

ID

}

Edi

X7$

*

X5$

*

X4@]

Set event target IP address

EX7$

ID

}

X5$

*

X4@]

Password and security settings
Set administrator password

24

EX7@

CA

}

Ipa•

X7(]

Set administrator access
password

X7@

.

X7@

= 4 to 12 alphanumeric

characters. The password is case
sensitive. Special characters
(spaces or symbols) are not
allowed.

X7(

= hidden password, shown

as four asterisks (****) if a

password exists; empty if not.

View administrator password

24

E

CA

}

X7(]

Reset (clear) administrator

24

password

E

•CA

}

Ipa•

]

Clear or remove all passwords
(administrator and user).

Set user password

14,34

EX7@

CU

}

Ipu•

X7(]

Set user access password

X7@

.

X7@

= 4 to 12 alphanumeric

characters. The password is case
sensitive. Special characters
(spaces or symbols) are not
allowed.

X7(

= hidden password, shown

as four asterisks (****) if a

password exists; empty if not.

NOTE: A user password cannot be assigned if an administrator password does not exist. Entering a password when the

AVT has not been configured yields an E14 error response from the tuner. If the administrator password is cleared
(removed), the user password is removed also.

View user password

E

CU

}

X7(]

Reset (clear) user password

E

•CU

}

Ipu•

]

Clear or remove the user
password.

Query session security level

E

CK

}

X8*]

In verbose mode:
Pvl

X8*]

Remap Port Destinations

NOTES:

Duplicate port number assignment are pnot permitted (for example, the Telnet and web mapping cannot be the

same. An E13 (invalid parameter) error code results.

Remapping of the port number other than to reset to defaults 80 or 23, or to disable by resetting it to 0 can be

done only to ports 1024 or higher.

Set Telnet port map

24

EX4@

MT

}

Pmt

X4@]

X4@

= Telnet port number

Reset Telnet port map

24

E

23MT

}

Pmt00032

]

Disable Telnet port

E

0MT

}

Pmt00000

]

View Telnet port mapping

E

MT

}

X4@]

Advertising