This adapter is designed for installation in new stud wall constructions, before installing
the gypsum board walls (drywall). For complete information about installing AVTrac, see
the AVTrac User Guide, which is available online at

www.extron.com

.

1.

Determine where AVTrac will meet
the wall. Cut out a section of the
wall base stud that is 4 inches
(10.1 cm) wide and align the front
edge of the adapter base with the
front edge of the wall base stud.

2.

Mark the position of the holes in the
adapter base, drill at least two holes
into the concrete 5/32 inches (0.4 cm)
diameter and 1 1/2 inches (3.8 cm)
deep, and secure the adapter to the
floor, using the provided masonry
screws.

3.

Cut a notch 1.5 inches (3.8 cm) high x
4 inches (10.1 cm) wide in the bottom
edge of the drywall and place the
drywall over the rough‑in adapter with
the top edge of the notch resting on
top of the front support of the adapter.
Secure the drywall to the wall frame.

4.

Install the AVTrac system (see the AVTrac
User Guide
, which is available online at

www.extron.com

).

Wall Base Stud

Rough-In Adapter

Front edge of the
adapter base is level
with wall base stud.

(2) Masonry
Screws

Dry Wall

Rough-In Adapter
Front Support

4.0"

1.5"