Signal test points, Figure 12. wiring a single speaker – Extron Electronics CS 120P User Guide User Manual

Page 15

Advertising
background image

16.

Attach the speaker wires to the captive screw connector

ATTENTION: Do not tin the wires. Tinned wires do not remain tight in the captive

screws and can break easily after several bends.

Number of Wires per Connection Point

Maximum Wire Gauge

1

12 AWG

2

16 AWG

4

18 AWG

Attach the speaker wires to the included four-pole captive screw connector using one of
the following methods:

Wiring a Single Speaker: Connect the wires to the captive screw connectors of
the speakers as shown in figure 12. Be sure to tighten the screws.

Wiring a Single Speaker

Speaker 1

IN

LOOP

IN

+

LOOP

+

(Red)

(Black)

Power Amplifier

Figure 12.

Wiring a Single Speaker

Wiring Multiple Speakers in Parallel: Connect the wires to the captive screw
connectors of the speakers, as shown in figure 13. Be sure to tighten the screws.

Wiring Multiple Speakers in Parallel

Speaker 1

Speaker 2

IN

LOOP

IN

+

LOOP

+

IN

LOOP

IN

+

LOOP

+

(Black)

(Red)

(Red)

(Black)

Power Amplifier

(Black)

(Red)

Figure 13.

Wiring Multiple Speakers in Parallel

In the parallel configuration, all of the speakers downstream of the one being tested
continue to function even when it is disconnected. This is especially useful in
installations where the system can never be completely down, such as in a hospital
setting.
The source signal can be tested by connecting to the inner

+ (IN) and (IN)

terminals of the captive screw connector.

Signal Test Points

Red Wire (+) from Amplifier

Black Wire (-) from Amplifier

Amplifier

Test Points

Figure 14.

Signal Test Points — Parallel Configuration

CS 26T and CS 120P User Guide • Installation