Extron Electronics DVS 605 Setup Guide User Manual

Dvs 605 • setup guide, Installation, Mounting and cabling

Advertising
background image

1

Mounting and Cabling

Step 1 — Mounting

Turn off or disconnect all equipment power sources and rack mount the
DVS 605 unit using the pre-installed brackets (see figure 1 at right).
Optional furniture mounting brackets (MBU 149) can be used to mount
the unit under a table or desk top (see figure 2 at right).

Step 2 — Connect inputs

Connect inputs from video sources to the applicable connectors
marked “Inputs”. See

a

and

b

for video connectors and

c

for audio connectivity.

Step 3 — Connect outputs

Connect video and audio output devices to the applicable connectors marked
“Outputs” (see

d

through

j

above).

Step 4 — Connect control devices

LAN port

l

— Connect a LAN or WAN via this RJ-45 connector

for remote control of the DVS 605 using an Internet browser via
a connected PC.

NOTES:

Default IP address is 192.168.254.254

• DHCP is disabled.

One connection LED lights green when connected to the LAN and one flickers
amber as the devices communicate.

NOTE: Do not use standard telephone cables for LAN connection, as they do

not support Ethernet or Fast Ethernet.
Do not stretch or bend cables as transmission errors could occur.

RS-232/IR port — For serial RS-232 control, connect a host computer or
control system to the 5-pole captive screw connector

m

.

RS-232 protocol (default values):
9600 baud, 1 stop bit, no parity, 8 data bits, no flow control.
By default the IR port is disabled.
Contact closure port — For remote input selection of any of the five inputs, connect a suitable contact closure control device to the
5-pole captive screw connector

n

. The contact closure port and the RS-232 port share a common ground.

Step 5 — Connect power

AC power connector — Plug in a standard IEC power cord from a 100 - 240 VAC, 50 - 60 Hz power source into this receptacle

o

.

DVS 605 • Setup Guide

The Extron DVS 605 Digital Video Scalers are scaling products that allow most common signal formats to be processed, scaled, and
output in any desired format. This setup guide allows an experienced user to easily and quickly set up and configure a
DVS 605 using step by step instructions. It covers how to perform basic operations using the front panel controls and selected
Simple Instruction Set (SIS

) commands.

NOTE:

For full installation, configuration, menus, connector wiring, and operation details, see the DVS 605 User Guide, available at

www.extron.com

Rack Mount
Bracket

L

1

R

L

2

R

L

3

R

L

4

R

L

5

R

L

FIXED

R

L

VARIABLE

R

100-240 VAC ~ .7A MAX

50/60Hz

RGB/R-Y, Y, B-Y

1

5

2

3

4

UNIVERSAL

AUX

HDMI

HDMI

GENLOCK

3G/HD - SDI

RS-232 IR

Tx Rx

S

G

G

CONTACT

1 2 3 4 5

S/PDIF

FIXED

LAN

RESET

INPUT

OUTPUTS

REMOTE

AUDIO INPUTS

AUDIO OUTPUTS

DVS 605 AD

14

13

7

6

2

3

8

9

10

15

4

5

1

11 12

Installation

Rear Panel Features

The DVS 605 AD is shown here. All other DVS 605 models have some but not all of the features shown below.

Figure 1.

Rack Mount

Figure 2.

Furniture Mount

#8 Screw

(4) Places

Each Side

MBU 149

Mounting Bracket

Mounting Screws

(2) Places

Each Side

Advertising