Rear panel, A note on i/o boards, A note on i/o boards -2 – Extron Electronics Fiber Matrix 6400 User Manual

Page 8: Installation, Fiber matrix 6400 switcher • installation, Fiber optic connectors and leds — see page 2-4, Sdi/hdi-sdi bnc connectors — see page 2-5, Ethernet connection (lan connector) — see page 2-5, Remote port — see page 2-5, Power connectors — see page 2-5

Advertising
background image

2-2

Refer also to the Fiber Matrix 6400 Switcher User’s Manual at

www.extron.com

.

Refer also to the Fiber Matrix 6400 Switcher User’s Manual at

www.extron.com

.

Rear Panel

A note on I/O boards

See figure 2-1. Each I/O board is identified by the input

and output numbers supported by the board position. The

transceiver modules on the I/O boards are identified as A

through H.

RESET

RS232/RS422

REMO

TE

LAN

A

CT

LINK

1 - 8

9 - 16

17 - 24

25 - 32

33 - 40

OUT

IN

A

OUT

IN

B

OUT

IN

C

OUT

IN

D

OUT

IN

A

OUT

IN

B

OUT

IN

C

OUT

IN

D

OUT

IN

OUT

IN

OUT

IN

OUT

IN

MUTI-RATE SDI INPUTS

H

G

A

D

E

F

C

B

Slot 1

Fiber optic

Inputs 1-8

Outputs 1-8

Output 1

Input 1

Slot 2

Fiber optic

Inputs 9-16

Outputs 9-16

Slot 3

No board

installed

Slot 4

SDI/HD-SDI

Inputs 25-32

Outputs 25-32

Output 2

Input 2

Output 3

Input 3

Output 4

Output 9

Output 10

Output 11

Output 12

Input 4

Input 25

Input 26

Input 27

Input 28

Input 29

Input 30

Input 31

Input 32

Input 9

Input 10

Input 11

Input 12

Figure 2-1 — Arrangement of inputs and outputs on
the I/O boards

The board position designators correspond to the input and

output numbers served by that position (1 - 8, 9 - 16, and so on).
The location designators, A through H on each board correspond

to the transceiver modules, numbered from left to right, each of

which includes an input and an output.
See figure 2-1. The input and output numbers supported by the

I/O board in location 9 - 16 are as follows: A = 9, B = 10, C = 11,

D = 12, E = 13, F = 14, G = 15, and H = 16.)

Figure 2-2 — Fiber Matrix 6400 Switcher rear panel

a

Fiber optic connectors and LEDs — See page 2-4.

b

SDI/HDI-SDI BNC connectors — See page 2-5.

c

Ethernet connection (LAN connector) — See page 2-5.

d

Remote port — See page 2-5.

e

Power connectors — See page 2-5.

f

Power indicator LEDs — See page 2-5.

ANAHEIM, CA

RESET

RS232/RS422

REMO

TE

LAN

A

CT

LINK

1 - 8

9 - 16

17 - 24

25 - 32

33 - 40

41 - 48

49 - 56

57 - 64

100-240V 50/60Hz

2A MAX.

100-240V 50/60Hz

2A MAX.

REDUNDANT

PRIMARY

PRIMARY POWER SUPPLY

REDUNDANT POWER SUPPLY

OUT

IN

A

OUT

IN

B

OUT

IN

C

OUT

IN

D

OUT

IN

E

OUT

IN

F

OUT

IN

G

OUT

IN

H

OUT

IN

A

OUT

IN

B

OUT

IN

C

OUT

IN

D

OUT

IN

E

OUT

IN

F

OUT

IN

G

OUT

IN

H

OUT

IN

A

OUT

IN

B

OUT

IN

C

OUT

IN

D

OUT

IN

E

OUT

IN

F

OUT

IN

G

OUT

IN

H

OUT

IN

A

OUT

IN

B

OUT

IN

C

OUT

IN

D

OUT

IN

E

OUT

IN

F

OUT

IN

G

OUT

IN

H

OUT

IN

A

OUT

IN

B

OUT

IN

C

OUT

IN

D

OUT

IN

E

OUT

IN

F

OUT

IN

G

OUT

IN

H

OUT

IN

A

OUT

IN

B

OUT

IN

C

OUT

IN

D

OUT

IN

E

OUT

IN

F

OUT

IN

G

OUT

IN

H

MUTI-RATE SDI INPUTS

H

G

A

D

E

F

C

B

MUTI-RATE SDI OUTPUTS

H

G

A

D

E

F

C

B

MUTI-RATE SDI INPUTS

H

G

A

D

E

F

C

B

MUTI-RATE SDI OUTPUTS

H

G

A

D

E

F

C

B

6

6

3

4

1

2

5

1

2

3

Fiber Matrix 6400 Switcher • Installation

Installation

Fiber Matrix 6400 Switcher • Installation

2-3

Advertising