Fls 101 function buttons, Measuring optical power, Power button – Extron Electronics Fiber Optic Test Set Setup Guide User Manual

Page 3: Multimode (mm) wave id / cw select

Advertising
background image

3

FLS 101 Function Buttons

Power Button

Press and hold to toggle the FLS 101 On or Off.

POWER

Multimode (MM) WAVE ID / CW Select

This button provides two functions:

MM

CW

850nm

1300nm

z

Press and release to cycle through output wavelengths in the
following order:
Dual 850/1300 nm > 850 nm > 1300 nm > dual 850/1300 nm > ...

z

Press and hold to switch to CW mode at the current
wavelength, then press and hold the button again to select a
single wavelength in the following order:
850 nm > 1300 nm > 850 nm ...

NOTE: To switch back to WAVE ID mode, press and release the

button again.

Measuring Optical Power

NOTE: It is important to keep all optical connections and surfaces clean to ensure

accurate measurements and operation. Always clean reference cables before
conducting tests.

1.

Turn on the FPM 101.

2.

Select the appropriate fiber optic reference cable. The reference cable fiber type
(SM or MM), must be the same as the type required by the output being measured.

3.

Mount the appropriate adapter cap on the FPM 101 port.

4.

Connect one end of the
reference cable to the adapter
cap and the other end to the
optical output to be measured.

5.

Press the wavelength button
(see

“Wavelength/Backlight”

on page 1) to select the
wavelength matching the
nominal wavelength of the
source being measured. The
selected wavelength is indicated
by

e

in the display.

6.

Press the power selection
button (see

“dB/dBm/µW”

on

page 1) to display power in
dBm, or press and hold to display
power in µW. The power output
is indicated by

f

in the display.

0000

0.00

WAVE ID

nm

Hz

µW

dB

0000

0.00

nm

Hz

µW

dB

λ

Ref

dBm

dB

µW

Set

POWER

Fiber Optic Equipment

a

f

e

c

d

b

d

Reference Cable

Adapter Cap

FIBER POWER METER

FPM 101

e

f

Advertising