Extron Electronics Fiber Optic Cables Cleaning User Manual

Fiber optic cables • cleaning instructions, Connectors, Fpm/fls 101 adapters

Advertising
background image

Fiber Optic Cables • Cleaning Instructions

Optimum optical performance is obtained when the reference cable connectors and the
FPM/FLS 101 adapters are properly cleaned. Perform the following procedures prior to use.

WARNING: Always handle, use and dispose of chemicals in accordance with

manufacturer’s safety instructions. Some chemicals may be toxic if swallowed.

Connectors

1.

Moisten a lint-free wipe with alcohol (damp, but not saturated), or use a pre-moistened
wipe.

2.

Wipe the ferrule end-face in a twisting/wiping motion.

3.

Repeat twice, using a clean area of the dampened wipe each time.

4.

Repeat wiping action using a dry lint-free wipe.

5.

Inspect the end-face under magnification (100x minimum) to ensure debris and
contaminants are removed.

FPM/FLS 101 Adapters

1.

Moisten the end of a lint-free swab with alcohol.

2.

Remove excess alcohol from the swab with a dry, clean wipe.

3.

Insert the swab into either end of the adapter.

4.

Clean, using a scrubbing motion.

5.

Remove the swab using a rotating motion.

6.

Using clean, compressed air, blow out the adapter until dry.

WARNING: Always wear eye protection when using compressed air. Never inspect or

look into the end of terminated fibers as invisible laser radiation may damage eye
tissue.

68-2103-01

Rev.

A

04 11

Equipment and Supply Requirements

The following items are recommended for cleaning the reference cable.

Isopropyl

Alcohol

Lint-free

Optical Wipes

or

Microfiber

Woven Wipes

Pre-moistened

Towelette

Oil-free

Compressed Air

Lint-free

Swabs

Magnifier

Advertising