The Extron EWB Series External Wall Boxes allow a variety of Extron products to be mounted to the surface of an interior
wall. The 2.5 inch (6.4 cm) depth accomodates an Extron product and cabling. This guide provides information for a
qualified, experienced installer to install an EWB wall box.

EWB External Wall Box Models

EWB 104
4-gang EWB

EWB 105
5-gang EWB

EWB 103
3-gang EWB

EWB 102
2-gang EWB

EWB 101
1-gang EWB

Recommended Fasteners

Choose the appropriate type of screw or bolt for the wall (see table below). The mounting holes in the back of the EWB
accommodate screws up to ¼ inch in diameter.

Wall Type

Fasteners

Min. Size Fastener Quantity

Drill Bit Size

Notes

Drywall

Toggle bolts

3/16 inch

At least 4

1/2 inch

Min. 3/8 inch wall thickness

Solid wood

Wood screws

#10 with a washer

At least 4

Not required

Min. 3/8 inch wall thickness

Masonry

Masonry screws 1/4 inch

At least 4

3/16 inch masonry bit

Do not mount to masonry joints.

Grounding

The rear inside panel has a PEM

®

#6‑32 insert for grounding; a grounding screw is included with each EWB.

Mounting the EWB

NOTES: This unit must be installed in accordance with the National Electrical Code and with all local codes.

z

z

Ensure that the installation meets the local and state regulatory requirements, including building,
electrical, and safety codes, and UL and ADA accessibility requirements.

z

z

Ensure that there are no utility cables or pipes at the intended location that might be damaged or cause
injury when installing the wall box.

The EWB can be mounted on any interior wall type. Knockouts allow for conduit or raceways to be run from the top,
bottom, or back of the box. Install the cables into the wall or conduits before mounting the EWB wall
box or installing any devices in the EWB. The installation instructions apply to all models.

Model

Part Number

EWB 101

(black, white)

60‑1161‑02, ‑03

EWB 102

(black, white)

60‑1162‑02, ‑03

EWB 103

(black, white)

60‑1163‑02, ‑03

EWB 104

(black, white)

60‑1164‑02, ‑03

EWB 105

(black, white)

60‑1165‑02, ‑03

Surface Raceway Knockouts

Size

Dimensions

Quantity

per EWB

Small 0.9” H x 0.75” W

(2.3 cm H x 1.9 cm W)

2

Large 0.95" H x 2.0" W

(2.4 cm H x 5.1 cm W)

2

Mounting
Screws (4)

4

Installing the EWB Onto a Wall

1.

If mounting to standard wood wall studs, locate the center of the studs.

2.

Place the EWB against the wall in a suitable location. Use a level to ensure the box is
horizontal, and mark the position of the four holes.

3.

If required, drill four holes into the wall.

4.

Insert four screws (see the table above) and attach the EWB to the wall.

Contents

EWB External Wall Box Models ................................................1
Recommended Fasteners ........................................................1
Grounding ..............................................................................1
Mounting the EWB .................................................................1

Installing the EWB Onto a Wall ...........................................1
Attaching the EWB to an Existing In-wall Junction Box .......2

Advertising