Extron Electronics HR Cable BNC User Manual

Hr cable bnc termination instructions, Related tools and parts list

Advertising
background image

Shielding

Stripped Cable

(do not scale from illustration)

Outer
Insulation

3/32" (2.4 mm)

Conductor

3/8"

(9.5 mm)

15/32"

(11.9 mm)

1/4"

(6.4 mm)

2

Shielding

Outer

Insulation

Conductor

Ferrule

Color-coded

Heat Shrink Tube

Center

Pin

Support

Sleeve

BNC Plug Body

68-624-01

Rev. A

HR Cable BNC Termination Instructions

Center Pin

3

Crimp Center Pin

Center Pin - flange flush
with edge of die

4

Extron Electronics, USA

1230 South Lewis Street
Anaheim, CA 92805
USA
714.491.1500
Fax 714.491.1517

Extron Electronics, Europe

Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
+31.33.453.4040
Fax +31.33.453.4050

Extron Electronics, Asia

135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
+65.383.4400
Fax +65.383.4664

Extron Electronics, Japan

Daisan DMJ Building 6F
3-9-1 Kudan Minami
Chiyoda-ku, Tokyo 102-0074 Japan
+81.3.3511.7655
Fax +81.3.3511.7656

www.extron.com

1

. Slide the color coded heat shrink tubing

over the cable, then slide the ferrule over the
cable. See the top diagram.

2

. Carefully strip the end of the

coaxial cable to expose the
shielding and inner conductor,
as shown at right.

3

. Insert the center

conductor into the center
pin.

4

. Insert the conductor and

pin into the crimp tool
with the appropriate die.

BNC Plug Body

5

6

Crimp Ferrule

7

Heat Shrink Tubing

8

With the flange on the center
pin flush with the edge of the
die, use the die’s 0.044” crimp
chamber (the smallest
chamber) to crimp the center pin.

5

. Insert the center pin into the BNC plug body

and slide the exposed shielding
over the support sleeve of the
BNC.

6

. Slide the ferrule over the

shielding and against the
BNC body.

7

. Using the die’s 0.240” crimp

chamber (the middle
chamber), crimp the ferrule.

8

. Slide the heat shrink tubing over the ferrule

and use a heat gun to set the heat shrink.

Related tools and parts list:

Crimp tool/die ............................................................. 100-045/046-01
Six conductor High Resolution, bulk, 500’ ............. 22-124-02
Male BNC HR connectors (qty. 30) ........................... 100-404-51
R, G, B, black, Y heat shrink HR/SHR, 1’ precut ... 39-024, 025, 026, 003, 027-03

Advertising