Extron Electronics IN3600 Series Preliminary Manual User Manual

Page 10

Advertising
background image

6

IN3606 / IN3656 / IN3666 OPERATION MANUAL - REV. 1.1 11/27/99

©1998 - INLINE, INC.

ScantX

X=Scan Time between Channels (i.e. [SCANT12.5] would set the scan time to 12.5
seconds)
Possible allowable times are:

2.5 seconds

5.0 seconds

7.5 seconds

10.0 seconds

12.5 seconds

15.0 seconds

17.5 seconds

20.0 seconds

22.5 seconds

25.0 seconds

27.5 seconds

30.0 seconds

32.5 seconds

35.0 seconds

37.5 seconds

REMOTE CONTROL OPERATION

The IN3600 Series switchers have a REMOTE CONTROL port which allows these units to be remotely
controlled. Channels can be selected through the remote port by providing contact closures between the
appropriate pins. The port also includes a +5V power supply and tally outputs. Several contact closure
type control devices are available including:

IN3590 - An optional hard wired remote designed to work with IN3600 Series switchers.

IN6901 / IN6902 RS232 to Contact Closure Converters - allow IN3600 Series switchers and
other INLINE devices with contact closure control ports to be controlled by RS232 sources such
as control systems and computer serial ports.

Control System - many control systems are capable of providing contact closures.

Control Parameters
In order to select a channel, the channel select pin (pins 1 - 6) must be connected to Common (pin 7 or 8).
The contact closures may be momentary or continuous (latching).

Example: To switch to Input Channel #4, apply a contact closure between Pin 4 and Pin 7.

Tally Output
The REMOTE CONTROL port also provides tally outputs (pins 10 - 15) which may be used to trigger
other devices, provide feedback to a control system, or light indicator lights on a custom remote control
panel. When a channel is selected, either from the front panel or through the REMOTE CONTROL port,
the Tally Output for that channel is switched on. The Tally Output can switch voltages of up to 50 volts
and current up to 1.5 amps.

Control Port Pin Outs
The REMOTE CONTROL port is a Female 15 Pin D connector with the
following pin outs:

Pin 1

Select Channel 1

Pin 9

+5 volts DC

Pin 2

Select Channel 2

Pin 10 *Tally output for Channel 6

Pin 3

Select Channel 3

Pin 11 *Tally output for Channel 5

Pin 4

Select Channel 4

Pin 12 Tally output for Channel 4

Pin 5

Select Channel 5

Pin 13 Tally output for Channel 3

Pin 6

Select Channel 6

Pin 14 Tally output for Channel 2

Pin 7

Common

Pin 15 Tally output for Channel 1

Pin 8

Common