Extron Electronics IN3526vi User Manual

Page 12

Advertising
background image

8

IN3526VI OPERATION MANUAL - REV. 2 12/01/98 ©1997 - INLINE, INC.

RS-232 COMMAND PROTOCOL

Command*

Function

Response*

ACI3

Set baud rate to 1200, default setting

OK

ACI4

Set baud rate to 2400

OK

ACI5

Set baud rate to 4800

OK

ACI6

Set baud rate to 9600

OK

ACI7

Set baud rate to 19200

OK

BLANK0

Blank output (no input selected)

OK or CH1

BLANK1

Un-blank output (selects previous input)

OK or CH1

CH0

Blank output (same as pressing the front panel BLANK button)

OK or CH1

CH1

Select Input 1

OK or CH1

CH2

Select Input 2

OK or CH1

CH3

Select Input 3

OK or CH1

CH4

Select Input 4

OK or CH1

CH5

Select Input 5

OK or CH1

CH6

Select Input 6

OK or CH1

CMDCD0

Select "[" & "]"

OK

CMDCD1

Select "{" & "}"

OK

CMDCD2

Select "(" & ")"

OK

CMDCD3

Select "<" & ">"

OK

SCAN0

Disable scan mode

OK

SCAN1

Enable scan mode

OK

SCANx

Configure scan to scan up to channel x where x = 2 to 6.

OK

SCANTx

Set scan time as follows:

x = 1: 2.5 seconds
x = 2: 5 seconds
x = 3: 7.5 seconds
x = 4: 10 seconds
x = 5: 15 seconds
x = 6: 20 seconds
x = 7: 30 seconds

OK

FP

Enable/Disable the front panel (toggle)

OK

FP0

Disable the front panel

OK

FP1

Enable the front panel

OK

INF0

Get the firmware version

IN3526VI V1.0

INF1

Get the currently selected input

0 to 6 (0 is for Blank)

* Command codes are not shown for clarification purposes.

RS-232 SAMPLE COMMANDS

Description

Command

Response

Switch to Input 2 (for a Slave switcher)

[CH2]

[OK]

Switch to Input 2 (for a Master switcher)

[CH2]

[CH1]

Get status of input selected

[INF1]

[2]

Disable Front Panel operation

[FP0]

[OK]

Change baud rate to 4800

[ACI5]

[OK]

Change command codes to { }

[CMDCD1]

{OK}

Advertising