Extron Electronics MDA 3 Series Setup Guide User Manual

Setup guide — mda 3 series, Setup guide — mda 3v series, cont’d, Installation

Advertising
background image

Setup Guide — MDA 3 Series

This card provides quick start instructions for an experienced

installer to set up and operate Extron MDA 3 Series

S-video, composite video, and audio distribution

amplifiers. See the table below right to identify the

attributes of each model covered in this guide.

Installation

Step 1 — Mounting

Turn off or disconnect all equipment power sources and

mount the MDA as required.

Step 2 — Connections

N

The drawings below may show features not on your

MDA, depending on your model.
The MDA 3V Dual has two separate DAs in a single
enclosure.

a

Input connector (MDA 3SV models) —

Connect an S-video video source

to the Input 4-pin mini DIN connector.

b

Output connectors (MDA 3SV models) — Connect up to three S-video displays to

these 4-pin mini DIN Output connectors.

MDA 3AV

POWER

12V

.34A MAX

L

R

L

R

L

R

L

R

INPUT

OUTPUTS

1

2

3

BAL

1 2 3

UNBAL

1

I

N

O
U

T

2

3

MDA 3AV,
Rear Panel

MDA 3SVA

POWER

12V

.5A MAX

L

R

L

R

L

R

L

R

INPUT

OUTPUTS

1

2

3

BAL

1 2 3

UNBAL

1

2

3

INPUT

OUTPUTS

MDA 3SVA,
Rear Panel

1

2

5

8

6

7

3

4

5

8

6

7

c

In connector (MDA 3V and 3AV models) — Connect a composite video

source to the BNC connector.

d

Out connectors (MDA 3V and 3AV models) — Connect up to three

composite video displays to these BNC connectors.

e

Input connector (MDA 3SV A, MDA 3AV, and MDA 3A) — Connect a

balanced or unbalanced stereo audio or mono audio device to the Input

5-pole captive screw connector. Wire the connectors as shown below:

L

R

Unbalanced Stereo Input

Balanced Stereo Input

(high impedance)

(high impedance)

Do not tin the wires!

Tip

Sleeve

Tip

Sleeve

Tip

Ring

Sleeve (s)

Tip

Ring

Distribution

Amplifier

Audio (captiv

e

screw connectors)

S-video

MDA 3V
MDA 3AV
MDA 3V Dual

MDA 3SV
MDA 3SVA

2

MDA 3A
2 = Two separate DAs.

Composite video

Setup Guide — MDA 3V Series, cont’d

68-607-50

Rev. A 01 10

Extron

USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517 FAX

Extron

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797 FAX

Extron

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664 FAX

Extron

Japan

+81.3.3511.7655

+81.3.3511.7656 FAX

Extron

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566 FAX

Extron

Middle East

+971.4.2991800

+971.4.2991880 FAX

© 2010 Extron Electronics. All rights reserved.

Power Supply

Output Cord

SECTION A–A

Ridges

Smooth

A

A

Captive

Screw

Connector

Tie
Wrap

3"
16 (5 mm)
Max.

f

Output connectors (MDA 3SV A, MDA 3AV, and MDA 3A) — Connect up to three

balanced or unbalanced stereo audio or mono audio devices to the Output 5-pole

captive screw connectors. Wire the connectors as shown below.

C

For unbalanced audio output, connect the sleeve(s) to the ground contact.

DO NOT connect the sleeve(s) to the negative (-) contacts).

L

R

Balanced Stereo Output

Unbalanced Stereo Output

Tip

Ring

Sleeve (s)

Tip

Ring

Sleeve(s)

L

R

Tip

Tip

NO GROUND HERE.

NO GROUND HERE.

Do not tin the wires!

g

Bal(anced)/Unbal(anced) DIP switches (Audio models) — For each

BAL

1 2 3

UNBAL

balanced audio output, set the associated DIP switch to the Balanced (up)

position. For each unbalanced audio output, set the associated DIP switch to

the Unbalanced (down) position.

Each output can be balanced or unbalanced independently of the other two

outputs.

h

Power connector — Connect an IEC power cord

between the included 12 V power supply and a

100 VAC/240 VAC, 50-60 Hz source. Connect the power

supply to the MDA as shown at right.

C

Always use a power supply supplied and or specified

by Extron. Use of an unauthorized power supply
voids all regulatory compliance certification and may
cause damage to the supply and the end product.
Unless otherwise stated, the AC/DC adapters are
not suitable for use in air handling spaces or in
wall cavities. The installation must always be in accordance with the applicable
provisions of National Electrical Code ANSI/NFPA 70, article 75 and the
Canadian Electrical Code part 1, section 16. The power supply shall not be
permanently fixed to building structure or similar structure..

Operation

After all devices are powered up, the system is fully operational. If any problems are

encountered, verify that the cables are routed and connected properly. If your problems

persist, call the Extron S

3

Sales & Technical Support Hotline that is closest to you, at the

number shown below.