Extron Electronics MSG0603 User Manual

Page 12

Advertising
background image

10

MSC0603 OPERATION MANUAL - v1.0 5/7/02

2002 - INLINE, INC.

Dipswitch settings


Dipswitch settings change according to the standard used. Higher standards require a different
signal type. Dipswitches make subtle adjustments to that signal type. Configure the dipswitch
settings according to the following table.

Serial Format

Dipswitch Settings

RS-232* 123

OFF

RS-422/RS-485 123

ON


*Factory default

Creating Presets


Once you create a switch or patch through the Output-Input method, you can assign it a Preset
number. This is a valuable, timesaving feature and allows unskilled operators the ability to
duplicate complex patches without having to actually configure the patch.

To create a preset:

1. Create the desired configuration of input/output connections.

2. Press

the

Preset button.

3. Press any one of the Input or Output select buttons to pick a storage location for this

preset.

4. Be sure to label or notate each Preset you make.

5. To recall a preset, press the Preset button, followed by the input/output button where the

preset was stored.

Key Concept

When you turn the MSC0603 on, it uses setup #1 as the
default, and this cannot change. If you plan on turning
off the MSC0603, make certain to store the initial
settings in setup #1.

Power-on Settings


To power the MSC0603 up, simply plug the unit it the outlet. There is no power on/off switch.

Reset to Factory Default


Soft Reset - To restore I/O configurations, volume levels, and the serial set up to the default
factory setting, press the 1 and 5 input buttons.

Hard Reset -
To restore all parameters, including presets, to the default factory setting, use the
[DFLTx] command.