Pre-installation

Pin

1

2
3
4
5
6
7
8

Wire color

White-green

Green
White-orange
Blue
White-blue
Orange
White-brown
Brown

Wire color

T568A

T568B

White-orange

Orange
White-green
Blue
White-blue
Green
White-brown
Brown

12345678

Insert Twisted

Pair Wires

Pins:

NOTE: If you are using Enhanced Skew-Free™ AV
cable, use the TIA/EIA T568A standard only.

The MTP R 15HD RSA D receiver can be installed in a one-gang electrical wall box with
a Decora wall plate cover (supplied).
Choose a location that allows cable runs without interference. Allow enough depth for
both the wall box and the cables. The box should be at least 2.5 inches (6.4 cm) deep
to accommodate the connectors and cables. Install the cables into the wall, furniture,
or conduits before installing the receiver.
The top image at right details the recommended termination of TP cables with RJ-45
connectors in accordance with the TIA/EIA T568A or TIA/EIA T568B wiring standards.
You can use either standard with CAT 5/5e/6 cable, but ensure that you use the same
standard on both ends of the cable.

Power Supply Wiring

Wire the power connector (see the image on the right). Verify the polarity before

Power Supply

Output Cord

SECTION A–A

Ridges

Smooth

A

A

Tie
Wrap

POWER
12V
xA MAX

Rear
Panel

Ridges

Earth
Ground

3/16"

(5 mm)

Max.

connection by plugging in the power supply with no load and checking the output

with a voltmeter.

Grounding guidelines

Extron MTP 15HD RSA D products can be adversely affected by electrostatic discharge)
(ESD) if they are not grounded correctly.
To prevent malfunctions or product damage, an experienced installer can correctly
ground an Extron MTP 15HD RSA D product grounding the power input port. Insert one
end of the grounding wire to the negative or ground pin on the power input connector
(see the image on the right). Tie the other end of the wire to an earth ground.
If you have any questions about how to ground a product in a specific application,
contact an Extron technical support specialist.
For more information and warnings, see “Power supply wiring” in the MTP R 15HD RSA D
User’s Manual
.

Installation

MTP 15HD RSA D Rx Rear Panel

INPUT

H SYNC +
V SYNC +
C SYNC
SOG
VIDEO
Bi-RS232

2

1

H SYNC +
V SYNC +
C SYNC

SOG
VIDEO
Bi-RS232

3

Connect/Configure the Rear Panel

a

DC power connector — If applicable, plug the external 12 VDC power supply into
this 2-pole captive screw connector (see power wiring details above).

b

Input connector — Connect the TP cable from the transmitter to this pigtail RJ-45
female connector (see the table above on the top right to wire the RJ-45 connectors).

c

DIP switches — Set the DIP switches to the desired preference (see

Set the DIP

Switches

on the next page for more details).