Preliminar y, Control connection, Medialink switcher to an mlc – Extron Electronics MLS 406SA User Manual

Page 15: Medialink switcher to an ir link, Tx rx ir +12v a b c, Medialink switcher to a computer or control system

Advertising
background image

2-

MLS 304 Series, MLS 406 Series • Installation

PRELIMINAR

Y

RS-232/MLC/IR

Tx Rx IR

12V

A B C

Transmit (Tx)

Receive (Rx)

Sleeve(s)

+12 V, 0.4 A power output

Ground ( )

Control connection

f

RS-232/MLC/IR control port —You can control the MLS switcher via an

RS-232 connection directly from a host computer, a control system, or a

MediaLink Controller (MLC). Alternatively, you can use IR remote control

via an Extron IR Link connected to this port.

Connect a cable between this port and an optional

Extron MLC MediaLink Controller or an optional

IR Link IR signal repeater.

• The MLC provides remote control of input switching

and volume.

• The IR Link accepts modulated IR signals

from a remote control so the remote control

can be used for selecting the switcher’s

inputs.

Extron Comm-Link cable is recommended

for this connection. If you use Comm-Link

cable, the switcher and controller (MLC) can be up to 250 feet (76.2 m) apart.

Wire the captive screw connector for connection to an IR Link, an MLC, or a

computer or control system as shown in the following four diagrams.

RS-232
MLC/IR

MediaLink Switcher to an MLC

MediaLink
Switcher
rear panel
RS-232/MLC/IR port

NOTE

The switcher provides up to 12 VDC, 0.40 A power to an MLC 206.

Other MLC models may draw more current than the MLS can provide.

Extron recommends using a separate power supply for the MLC.

Ground ( )

+12 VDC input

NOTE

If you use cable that has a

drain wire, tie the drain wire

to ground at both ends.

RS-232
MLC/IR

MediaLink Switcher to an MLC

that has an external power supply

MediaLink
Switcher
rear panel
RS-232/MLC/IR port

NOTE

If using an external power

supply (instead of the MLS) to

power the MLC, you must

connect a ground wire

between the MLC and MLS.

NOTE

If you use cable that has a

drain wire, tie the drain wire

to ground at both ends.

RS-232_MLC-IR port wiring_MLS304_062404.eps

RS-232
MLC/IR

Tx Rx IR

+

12V

Tx Rx IR

+

12 V

Tx Rx IR

+

12V

MediaLink Switcher to an IR Link

MediaLink
Switcher
rear panel
RS-232/MLC/IR port

IR Link

port

A B C

A B C

A B C

MediaLink Switcher Rear Panel

RS-232
MLC/IR

Tx Rx IR +12V

A B C

MediaLink Switcher Rear Panel

RS-232
MLC/IR

Tx Rx IR +12V

A B C

MediaLink Switcher Rear Panel

RS-232
MLC/IR

Tx Rx IR +12V

A B C

RS-232
MLC/IR

RS-232 port

of a

computer or

control system

MediaLink Switcher to a

computer or control system

MediaLink
Switcher
rear panel
RS-232/MLC/IR port

NOTE

Connect a ground wire

between the MLC and the

computer or control system.

NOTE

If you use cable that has a

drain wire, tie the drain wire

to ground at both ends.

Tx Rx IR

+

12V

A B C

MediaLink Switcher Rear Panel

RS-232
MLC/IR

Tx Rx IR +12V

A B C

Host Computer

Control System

or

Ground ( )

+12 VDC

Transmit (Tx)

B Receive (Rx)

A

Ground ( )

Transmit (Tx)

B Receive (Rx)

A

Ground ( )

Transmit (Tx)

B Receive (Rx)

A

250 feet (76.2 m) maximum

150 feet (45.7 m) maximum

Ground ( )

+12 VDC

IR (IR Link)

C

IR Link

MLA-Remote

SIGNAL

IR

A B C D E

D

D

VD

MLC
MLS/Power
port

MLC
MLS/Power
port

A B

MLS / Power

Transmit (Tx)

Receive (Rx)

+12 VDC

Ground ( )

B

A

A B

MLS / Power

Transmit (Tx)

Receive (Rx)

B

A

Transmit (Tx)

Receive (Rx)

3

2

Ground all devices

External

Power Supply

(12 VDC, 1A max.)

External

Power Supply

MediaLink

Controller

(MLC)

MediaLink

Controller

(MLC)

Advertising
This manual is related to the following products: