The maximum distance is determined by the frequency and resolution of the signal that
is input to the transmitter. The

table

on page 4 specifies the recommended maximum

transmission distances and transmitter Pre-Peak switch positions (see

item

e

on page 9)

using Extron Enhanced Skew-Free A/V UTP cable, STP201 cable, or CAT 5, 5e, 6, or 7 cable,
terminated with RJ-45 connectors.

NOTES:

The non-C7 transmitter and receiver are designed for and perform best with

Extron Enhanced Skew-Free A/V UTP cable terminated in accordance with
the TIA/EIA T 568 A wiring standard. CAT 5, 5e, and 6 cables are acceptable
for the non-C7 models, but less preferable. We also recommend the use of
pre-terminated and tested cables. Cables terminated on site should be tested
before use to ensure that they comply with CAT 5 specifications.

The use of STP201 or CAT 7 cable with non-C7 products has a negative effect

on transmission distance. STP201 or CAT 7 cable should only be used with C7
products.

Extron recommends using at least 25 feet of TP cable between the transmitter

and the first receiver.

For daisy-chained units, the first receiver in the chain must be at least

100 feet (30 m) from the transmitter when the Pre-Peak switch is on.

For daisy-chained units, any receiver in the chain closer than 350 feet (105 m)

may experience some form of overpeaking when the Pre-Peak switch is on.
An overpeaked image may appear bloomed.