Output connections, Connections, Ipa t rly4 • connections 3 – Extron Electronics IPA T RLY4 User Manual

Page 4

Advertising
background image

IPA T RLY4 • Connections

3

Connections

N

Figure 3 is a wiring diagram of a typical application: an Extron

MLC 104 IP Plus controlling an IPA T RLY4 relay function.

Refer to the

MLC 104 Plus Series Manual for information on

configuring the MLC to control the IPA T RLY4.

1
2
3

GROUND

+12V OUT

CM

GROUND

IR OUT

GROUND

SCP

GROUND

Tx
Rx

DISPL

AY

RS-232/I

R

A B C D

E

COMM LINK

LAN

PRESS

TA

B

WITH

TWEEKER

TO

REM

O

VE

A

B

MLS

RS-232

PO

WER

12V

DIGIT

AL

I/O

IR IN

Tx

GROUND

Rx

+12V IN

IP

A

T RL

Y4

1 2 3 4

C

INPUTS

MLC 104 IP Plus
Right Side

Observe proper polarity when making connections to the
MLC 104 IP Plus controller’s Power port.
Miswiring can damage the controller’s Digital I/O port.

IPA T RLY4
Front Panel

Relay 1

Relay 2

Relay 3

+12 VDC

CAUTION

Figure 3 — Wiring diagram for connection to an
MLC 104 IP Plus

Output connections

b

Outputs — For each relay:

For the normally open contacts

, connect a device between the NO

and C terminals of the 3-pole captive screw connectors.

For the normally closed contacts

, connect a device between the

NC and C terminals of the 3-pole captive screw connectors.