Command and response table for sis commands, Command and response table for, Sis commands – Extron Electronics MSW 4V rs User Guide User Manual

Page 25: Commands

Advertising
background image

Command and Response Table for SIS Commands

Command

ASCII Command
(host to unit)

Response
(unit to host)

Additional Description

Input selection

Select input

X!

!

In

X!]

Selects input (

X!

1 to 4)

Input video sensing

Request status of all inputs

0S

Sig

•X@•X@•X@•X@]

Each

X@

response is the signal status of an

input, from input 1 to 4.

X@

= 0 (no signal) or

1 (signal detected).

Example:

0S

Sig

1

0

0

1

]

Input 1 = signal present; input 2 = no signal
present; input 3 = no signal present; input 4
= signal present.

Request the status of an
individual input

X!

S

X@]

Signal status for input

X!

is

X@

Video mute

Mute or unmute video

X#

B

Vmt

X#]

Toggles between video mute and unmute;

X#

= 0 (unmute) or 1 (mute).

Read mute status

B

X#]

Shows mute status.

Mode select

Normal/auto switch mode

X$

#

F

X$]

Toggle between normal and autoswitch
modes.

X$

= 1 (normal) or 2 (auto)

Information Requests

General information

I

V

X%•

F

X$•

Vmt

X#]

For currently selected input

X%

(1 to 4)

switcher is in

X$

mode (1 = normal, 2 = auto)

and video mute status is

X#

(0 = unmute, 1

= mute).

Example:

I

V2

F1

Vmt0

]

Video is selected on input 2; switcher is in
normal mode (F1); video mute is off.

Query firmware version

Q

x.xx

]

View the firmware version.

Query part number

N

60-480-xx

]

View the part number (60-480-11 or
60-480-12).

Upload firmware

E

Upload

}

Go

]

Upload firmware.

System reset (factory default)

E

Zxxx

Zpx

]

Resets unit to factory defaults.

MSW 4V rs and MSW 4SV rs • SIS Commands

19

Advertising
This manual is related to the following products: