Mtp da4 and da8 • setup guide, Operation — mutes, Step 4 — power – Extron Electronics MTP DA8 Setup Guide User Manual

Page 2

Advertising
background image

68-975-50 Rev. D

01 13

Extron Headquarters
+800.633.9876 Inside USA/Canada Only

Extron USA - West

Extron USA - East

+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX

+1.919.850.1001 FAX

Extron Europe
+800.3987.6673
Inside Europe Only

+31.33.453.4040
+31.33.453.4050 FAX

Extron Asia
+800.7339.8766
Inside Asia Only

+65.6383.4400
+65.6383.4664 FAX

Extron Japan

+81.3.3511.7655
+81.3.3511.7656 FAX

Extron China
+4000.EXTRON
+4000.398766
Inside China Only

+86.21.3760.1568
+86.21.3760.1566
FAX

Extron Middle East

+971.4.299.1800
+971.4.299.1880 FAX

Extron Korea

+82.2.3444.1571
+82.2.3444.1575 FAX

Extron India
1800.3070.3777
Inside India Only

+91-80-3055.3777
+91 80 3055 3737
FAX

©

2013 Extron Electronics All rights reserved.

www.extron.com

MTP DA4 and DA8 • Setup Guide

Step 4 — Power

Power Supply

Output Cord

SECTION A–A

Ridges

Smooth

A

A

Wire the 2-pole captive screw connector for the external 12 VDC power supply
(see the image on the right).

Grounding the Power Input Port

Extron MTP DA products can be adversely affected by electrostatic discharge
(ESD) if they are not grounded correctly.
To prevent malfunctions or product damage, an experienced installer can correctly
ground an Extron MTP DA product by inserting one end of the grounding wire to
the negative or ground pin on the power input connector (see the image on the
right). Tie the other end of the wire to an earth ground.
Plug the connector into the MTP DA.
If you have any questions about how to ground a product in a specific application,
contact an Extron technical support specialist.

Operation — Mutes

To mute an output, tie the Output Mute pin to the ground ( ). To mute all outputs, tie the A pin to the ground (see figure

2

for more

information).

1 2 3 4 5 6 7 8 A

MTP DA8

Output Mute Connector

1 2 3 4 A

MTP DA4

Output Mute Connector

Pin

Contact

Closure

Function

1

Out #1

Mute output #1

2

Out #2

Mute output #2

3

Out #3

Mute output #3

4

Out #4

Mute output #4

5

Out #5

Mute output #5

6

Out #6

Mute output #6

7

Out #7

Mute output #7

8

Out #8

Mute output #8

A

Out All

Mute all output

Gnd

Ground

0.5A M

AX

12V

PO

WE

R

+

-

OUTPUT

MUT

E

1

2

3

4

5

6

7

8 A

INP

UT

1

2

3

4

5

6

7

8

OUTPUT

S

OU

TP

UT

SHAR

P

L

R

INP

UT

VID

EO

12V

0.5a

MA

X

MTP

R S

V A

OU

TP

UT

SHAR

P

L

R

INP

UT

VID

EO

12V

0.5a

MA

X

MTP R S

V A

OU

TP

UT

SHAR

P

L

R

INP

UT

VID

EO

12V

0.5a

MA

X

MTP

R S

V A

OU

TP

UT

SHAR

P

L

R

INP

UT

VID

EO

12V

0.5a

MA

X

MTP

R S

V A

INPU

T

MTP T

SV A

RC

A

VID

EO

OUT

PUT

L

R

12V

0.5a

MAX

Flat Panel

Display

Extron

MTP DA8

Twisted Pair

Distribution Amplifier

Up To

8 Receivers

Extron

MTP T AV RCA

Twisted Pair

Transmitter

DVD

Extron

MTP R AV

Twisted Pair

Receivers

TP Cable

TP Cable

Figure 2.

Mute Connector and Pinout

Figure 3.

Example of a Typical MTP DA8 Application

POWER
12V
xA MAX

Tie
Wrap

Rear
Panel

Ridges

Earth
Ground

3/16"

(5 mm)

Max.

Advertising
This manual is related to the following products: