Extron Electronics Replacing the AC Power Cord with Flexible Conduit User Manual

Ul guidelines, Removing the old cable

Advertising
background image

IMPO

RTAN

T:

Go to www

.extron.com

for the

complete user guide

, installation

instructions,

and specifications.

Replacing the AC Power Cord
with Flexible Conduit • Installation Guide

This guide provides instructions for replacing the power cord of an Extron Cable Cubby or Hideaway Surface Access (HSA) enclosure
with conduit (not provided) where required by local codes.

UL Guidelines

The Underwriters Laboratories (UL) guidelines listed below pertain to the installation of flexible conduit into an Extron Cable
Cubby or HSA.

WARNING:

Installation and service must be performed by a qualified electrician only.

This unit is not to be used beyond its rated voltage range.

This unit must be wired to a UL-listed distribution box. The installer is responsible for obtaining and installing the box.

This unit must be installed in accordance with the National Electrical Code and with all local codes.

Removing the Old Cable

WARNING:

Ensure power is removed from the Cable Cubby or HSA by disconnecting

the power cable from the electrical outlet.

1.

If the power module is installed in a Cable Cubby, remove the power module. If a
clamshell is installed on the base of the HSA, remove the clamshell.

NOTE:

If necessary, remove the

Cable Cubby or HSA from the
table in which it is installed.

2.

Unplug any devices plugged into the
sockets of the power module or HSA.

5.

Remove the sealing nut.

6.

Remove and retain the two screws on the power input plate on the bottom
of the power module or HSA. Gently pull out the plate and remove it from
the cut portion of the cable, leaving the wiring attached to the power
module.

NOTE:

If necessary, push the cable through the cord grip so that it is

not pulled by the plate.

7.

Remove the lock nut and cord grip
from the power input plate.

3.

For the Cable Cubby power module,
remove and retain the four screws on
the side and remove the side plate (see
image at right).

4.

Cut the power cable at approximately
0.5 inch below the sealing nut on the
power module or HSA.

Side Panel

Cut Cable 0.5"

Below Sealing Nut

4

3

Power Module

Remove Sealing Nut

Remove Power Input Plate

5

6

Cord Grip

Lock Nut

Power Input Plate
(power module)

Power Input Plate
(HSA)

Cut Cable 0.5"

Below Sealing Nut

4

HSA

Advertising