Setup Guide — PVT RGB D and AAP (w/EDID Minder

)

Installation

PVT RGB D

1.

Using the supplied mud ring or a junction box (not

included) as a guide, mark and cut out the appropriate

material within the marked area.

N

If installing a junction box, allow enough depth for
the wallplate, connectors, and cables. The depth
should be at least 2.0 inches (5.1 cm).

2.

Either:

Insert the mud ring into the opening, rotate the

locking arms, and secure with the supplied screws, or

Insert the junction box and secure with nails or screws.

3

. Run the CAT 5 cables from the PoleVault switcher

location, going behind the wall and to the PVT

location, then thread the cables through the mud ring

or wall box.

N

The CAT 5 cables supplied with the PoleVault system
are terminated to the TIA 568A standard. Other
CAT 5 cables can be used if they are TIA 568A or
TIA 568B standards and terminated to the same
standard at both ends.

PVT RGB AAP

1

. Before attaching any cables, insert the AAP standoffs

through the holes in the faceplate of the device or AAP

wallplate.

2

. Using the supplied #4-40 nuts and captive washers,

secure the AAP to the faceplate or wall plate.

3

. Be sure to include the AAP connectors as part of the

installation pretest before final faceplate installation.

N

For more detailed installation information, refer to

the installation guide shipped with the device.

The PVT transmitter should be cabled and tested
before it is finally installed into the wall or device
faceplate, as the rear panel connections will be
inaccessible after installation.

COMPUTER IN

AUDIO IN

IR OU

T

S G

Decora

®

Faceplate

Extron
PVT RGB D

Wall

Wall Mounting
Bracket

The Extron

®

PVT RGB D and AAP models with EDID Minder

are A/V wall and architectural plates for PoleVault

®

Systems. They transmit high-resolution computer video

and audio signals to the PoleVault switcher. These models

incorporate EDID Minder, which allows the transmitter

to send appropriate EDID information to the source ensuring

correct video output resolution. See reverse side for EDID Minder operation.

N

The EDID Minder settings DIP switch is located on the rear of the wallplate.
Once installed, switch settings are accessible only by removing the device from the
installed location. The factory EDID setting (default) is 1024x768@60 Hz (preset 2)

.

(Continued on other side)

RJ-45 Wiring Table

5

Pin

1

2
3

6
7
8

4

Wire Color

White-green

Green

White-orange

White-blue

Orange
White-brown
Brown

568A

Blue

Wire Color

568B

White-green

Green

White-orange

White-blue

Orange

White-brown
Brown

Blue

12345678

RJ-45

Connector

Insert Twisted

Pair Wires

Pins:

COMPUTER IN

AUDIO IN

IR OUT

S G

AAP 102

Extron
PVT RGB AAP

AAP 102

PVT RGB

COMPUTER

IN

AUDIO IN

PVT RGB AAP

IR

OUT

S
G

COMPUTER

IN

AUDIO IN

PVT RGB AAP

IR

OUT

S