SMD 101 • Setup Guide

The Extron SMD 101 decodes video or graphics streams from an IP network,
plays back internal video and audio files, and plays Video On Demand files from network shares at their original resolution or
scaled up or down to any common SD, HD, or graphics resolution up to 1900x1200 (WUXGA). The SMD 101 can be deployed in
live event streaming and high level conferencing for specialized projects.

Mount the SMD 101

Before connecting the SMD 101, turn off all devices that will be connected to it. The SMD 101 is housed in a 1-inch high,
half-rack width, 6-inch deep metal enclosure that can sit on a table with the provided rubber feet or can be rack mounted. Select
a suitable mounting location, then choose an appropriate mounting option.
Make all external device connections before applying power.

Rear Panel Overview

12V

1.0A MAX

POWER

HDMI

L

R

AUDIO

Tx Rx G

S G

RS-232

RESET

IR IN

LAN

OUTPUTS

1

2

6

3

4

5

7

Figure 1.

SMD 101 Rear Panel

a

12 VDC Power input

e

3.5 mm, 3-pole captive screw connector for dual mode

RS-232 port (host control or IP pass-through)

b

HDMI output

f

Reset button and LED

c

3.5 mm, 5-pole captive screw

connector for analog stereo audio
output

g

RJ-45 Ethernet connector for connection to a LAN

d

3.5 mm, 3-pole captive screw

connector for wired IR receiver input

Front panel USB config port (see

figure 4

,

e

)

Power Supply Connection

a

12 VDC power input – Connect the provided 12 VDC power supply to the rear panel captive screw connector (see figure 2)
and plug in the power cord. Verify the front panel power LED lights (see

figure 4

,

a

on page 4).

Rear Panel
Power Receptacle

DC Power Cord
Captive Screw
Connector

AC Power Cord

External

Power Supply
(12 VDC, 1 A )

POWER
12V
1.0A MAX

Figure 2.

External Power Supply Connection

ATTENTION:

Always use a power supply provided by or specified by Extron.
Use of an unauthorized power supply voids all regulatory
compliance certification and may cause damage to the supply
and the end product.

Unless otherwise stated, the AC/DC adapters are not suitable
for use in air handling spaces or in wall cavities. The power
supply is to be located within the same vicinity as the Extron
AV processing equipment in an ordinary location, Pollution
Degree 2, secured to the equipment rack within the dedicated
closet, podium, or desk.

The installation must always be in accordance with the
applicable provisions of National Electrical Code ANSI/NFPA
70, article 75 and the Canadian Electrical Code part 1, section
16. The power supply shall not be permanently fixed to
building structure or similar structure.