Extron Electronics RGB 580xi AAP Setup Guide User Manual

Installation, Step 1 — power down, Step 2 — connect the rear panel cables

Advertising
background image

Setup Guide — RGB 580xi AAP

and RGB 580xi CC AAP Series

This guide provides basic instructions for an experienced

installer to set up and operate the Extron RGB 580xi AAP

and RGB 580xi CC AAP.

Installation

The AAP device should be cabled before attaching the AAP

device to a faceplate or wall plate.

C

Installation and service must be performed by authorized personnel only.

Step 1 — Power down

Turn off or disconnect all equipment from power sources.

Step 2 — Connect the rear panel cables

Connect the cables to the AAP device’s rear connectors.

N

Although the control cable, LED, and audio assemblies come prewired to the captive screw

connectors, any subsequent cable assembly replacement requires the following instructions.

1

3

Example of AAP device rear connectors

2

Red

Black

White

Yellow

Pink

Orange

Green

Gray

Brown

Lt. Blue

Purple

J4

J2

Example of Cable Cubby AAP device rear connectors

1

2

To cable the captive screw connectors, refer to the following diagrams and orient the wires

according to the view angle of the captive screws. Use the Extron VGA and control cable

assembly and refer to the color of each wire for signal identification.

a

Control connector (J4)

— This connector is used for contact closure and horizontal shift

signals. Wire the appropriate connector as shown below.

Horizontal shift

+

(green)

Horizontal shift ground (gray)

Horizontal shift

(brown)

Contact closure

+

(light blue)

Contact closure

(purple)

Horizontal shift

+

(green)

Horizontal shift ground (gray)

Horizontal shift

(brown)

Contact closure

+

(light blue)

Contact closure

(purple)

Pin 1

Pin 1

(Continued on reverse side.)