Extron Electronics USFM 100 Bracket Kit Installation User Manual

Usfm 100 bracket kit • installation guide, Installation, The extron

Advertising
background image

The Extron

®

USFM 100 Bracket Kit consists of a single

mounting plate and three securing screws, and is used
for mounting an accessory device within the
USFM 100 Universal Short Throw Fixed Mount
enclosure. A single half rack device, or two quarter
rack devices, or two one-eighth rack devices can be
mounted on one plate, and up to four mounting
plates can be installed within a USFM 100 enclosure.

Installation

NOTE: Ensure the finished installation is in accordance with local and national

building codes, fire and safety codes, UL requirements, and local and
national electrical codes.

See the USFM 100 User Guide for details on how to install the USFM 100.

1.

If the USFM 100 is already installed,
remove the cover securing screws and
then remove the covers.

2.

Place the bracket kit mounting plate
flat against the accessory device base
with the small securing tab over the
front panel (see figure 2).

3.

Align the corresponding holes on the
plate with the two mounting holes in
the device base and secure the plate to
the device using the two 4-40 x ¼ inch
pan head screws (see figure 2).

NOTE: Quarter rack devices or

one-eighth rack devices can be
attached to the ends of the plate
as shown in figure 3.

4.

Hook the tabs on the mounting plate
(now with the accessory device attached)
under the tabs on the USFM 100 base
plate (see figure 4).

NOTE:

The mounting plate can be

installed in any available mounting
location (top or bottom) on the
USFM 100.

USFM 100 Bracket Kit Installation Guide

Figure 2.

Attach the Plate to the Device

(1) 4-40 x 3/16" screw

Device Mounting Plate

(2) 4-40 x ¼" screws

Figure 3.

Quarter Rack Device Attached

Figure 1.

USFM 100 Bracket Kit Parts

Device

Rear Panel

Mounting Plate

USFM 100 Base Plate
(Side View)

Tabs

(2) 4-40 x 1/4"
Screws

Accessory
Device

RG

B

PEAKI

NG

LEVEL

M

T

P

S

E

R

IE

S

¼ Rack Device

Figure 4.

Hook the Plate under the Tabs

on the USFM 100.

Advertising