2

RCP 2000 with ISS 506 Support Setup Guide (cont'd)

Affixing the Sub-effects Label

The Wipe and PIP Sub-effects label lists the transition effects

available to be displayed when the RCP is transitioning from the

preview input to the program input, or when it is opening or closing

the picture-in-picture (PIP) window. Attach this label to the RCP's

top panel, to the right of the H and V adjustment knobs.
1

.

Ensure that the area on which the label will be placed is dry

and free of debris.

2

.

Peel the backing off the label and center the label in the

designated area. See the illustration at right.

Replacing the Button Labels

Replace the specified program and preview button labels on the

RCP 2000's front panel with the provided button labels as indicated
in the table at the end of this section. See the "before and after" illustration to the right of the table.
Use the following procedure to install new labels in the RCP’s front panel buttons:
1.

Remove the button from the RCP by grasping the button firmly and pulling it away from the top panel.

2.

Use a small flat-head screwdriver to gently pry the transparent button cap off of the white backing plate.

3

.

Remove the white diffuser and the transparent label.

4.

Insert the appropriate button label into the cap (see the table below). If "None" is specified for the button you removed,

do not insert a label and skip to step 5.

5

.

Replace the diffuser in the transparent cap.

6

.

Gently but firmly press the cap onto the white backing plate.

7.

Press the button into place in the RCP top panel.

Button

Replace with:

Program 9

None

Program 10

None

Program 11

Logo1/Black

Program 12

Logo2/Black

Preview 9

None

Preview 10

Auto Image

Preview 11

Logo1/Black

Preview 12

Logo2/Black

Affixing the Updated Product Label

Replace the product label on the bottom of the RCP with the updated label, part #33-873-01, revision D, as follows:
1

.

Turn the RCP over in your lap or on a flat

surface. Be careful not to put excessive stress

on the T-bar handle.

2

.

Use a plastic card (such as a credit card) to pry

loose a corner of the attached label, and peel the

label off the RCP. Discard the old label. (Do

not use a screwdriver to remove the label as this

could chip the paint on the unit.)

3

.

Peel the backing off the new product label

(Rev. D) and affix it to the base of the RCP,

making sure to keep the label centered (see the

illustration at right).

RCP 2000 Remote Control Panel

Setting Up the IP Addresses

The following visual effects are available to be applied to transitions between the preview and the program
inputs or, on the RCP with ISS 506 only, when a picture-in-picture (PIP) opens or closes on the display.
Cut — Seamlessly replaces the program image with the preview image. On the RCP with ISS 506, this
effect also immediately opens or closes the PIP or title when either of these modes is active.
Dissolve — Causes the program input to fade out while the preview input is fading in. The dissolve duration
is adjustable from 0.0 to 5.0 seconds. Dissolve is available in PIP mode as sub-effect #01 (RCP with
ISS 506 only).
Wipe (SGS and ISS 506 only) — Causes the preview image or the PIP window to appear to unroll over the
program image. A variety of sub-effects are available in Wipe mode (21 for the standard RCP, 25 for the
RCP with ISS 506 support), including Standard, Curtain, Plus, and Square (refer to your user's manual
for complete descriptions). The sub-effect duration is adjustable from 0.0 to 5.0 seconds.
PIP (picture-in-picture, ISS 506 only) — When the system is in PIP mode, the preview image appears in a

small window within the program image on the display. 25 sub-effects are available in PIP mode.

Title — Causes the preview image of predefined intensity to be superimposed over the program image.

(The size of the title box is set on the SGS or the ISS 506.) Only the cut effect is available for displaying

and removing the title; the dissolve or wipe effects cannot be applied to it.

33-873-01 Rev.

D

08 08

1. Select the desired Preview (input), and press the preview input selection button to display the preview
image on the preview monitor.
2. Make adjustments (centering, size, detail, contrast/brightness, color/tint) to the preview image as necessary
(see “Adjusting an Image,” at left).
3. Select a type of transition effect (see “Transition Effects,” above).
4. If you selected a wipe transition, choose the desired wipe sub-effect.
5. Select the duration of the dissolve or wipe.
6. When you want the transition to occur, press the Take button or move the T-bar up or down.
Alternatives
For an instant, seamless transition, press the Cut button.
To freeze the output display, press the Freeze button.
To display a black screen, press the Black button.
• To recall logos that have been assigned on the ISS 506, press the Logo1 or Logo2 button (RCP with
ISS 506 only).
• To recall a user preset that was saved on the ISS 506, repeatedly press the preview input button
corresponding to the desired ISS 506 input to cycle through the user presets saved to that input (RCP with
ISS 506 only).
• To automatically size and center the preview input, press the Auto Image button (RCP with ISS 506 only).

Making a Transition

The RCP 2000 ships with default IP addresses for the client (RCP) and server (ISS 408, ISS 506, or SGS
switcher) already set. If you want to change these default addresses, follow these steps:
1. Slide the T-bar handle to the top or bottom of its slot.
2. Press and hold the following four buttons simultaneously until the LCD screen displays the unit’s MAC
address (xx-xx-xx-xx-xx-xx):
• Standard RCP (firmware version 2.nn) — Press and hold the Wipe, Dissolve, Cut, and Take buttons
simultaneously.

RCP with ISS 506 (firmware version 3.nn) — Press and hold the Color/Tint, Cont/Bright, Size, and

Center buttons simultaneously.

If you are not sure which firmware version is loaded, power off the RCP, then watch the LCD display while
powering the RCP back on.
3. Press the Take button. The Take, Cont/Bright, Size, and Center buttons light, and the Color/Tint
button blinks. The client (RCP) IP address (IP) is displayed on the LCD screen.
4. Press the appropriate picture control button, then turn the H Adjust knob to change each block of the
RCP’s IP address, as follows:
• Press the

Color/Tint button, then change the first block of the IP address.

• Press the

Cont/Bright button, then change the second block of the IP address.

• Press the

Size button, then change the third block of the IP address.

• Press the

Center button, then change the fourth block of the IP address.

5. Press the Take button again. The server (switcher) IP address (SI) is displayed on the LCD screen.
Repeat step

4 to change the server IP address.

N For RS-232 control (RCP with ISS 506 only), set the SI address to 0.0.0.0.

6. Press the Take button again. The Subnet Mask (SM) is displayed on the LCD screen. Repeat step 4
to change the Subnet Mask.
7. Press the Take button again. The Gateway (GM) address is displayed on the LCD screen. Repeat
step

4 to change the Gateway address.

8. When finished making changes, press the Detail button to exit and save the changes.

N Nothing happens if there is no momentary press.

Mode 1 – Holding the Reset button until the LCD display shows Reset Mode 1 (3 seconds), followed by a
momentary press (<1 second), stops all events. The LCD screen displays

Unit reset when reset is done.

Mode 2 – Holding the Reset button until the LCD display shows Reset Mode 2 (5 seconds), followed by a
momentary press (<1 second), erases all user flash memory, resets ports to defaults, and reboots the
unit. The LCD screen displays

Unit reset when reset is done.

Mode 3 – Holding the Reset button until the LCD display shows Reset Mode 3 (10 seconds), followed by a
momentary press (<1 second), resets the unit to factory defaults. The LCD screen displays

Unit reset

when reset is done.

Reset Modes

Button

H adjustment knob

V adjustment knob

To adjust the preview image, press and release the appropriate control button. The selected button lights.
Make adjustments with the H and V adjustment knobs.

Center

Move image horizontally

Move image vertically

Size

Adjust image width

Adjust image height

Detail (ISS 408 and SGS)

Select horizontal filter

Select vertical filter

Detail (ISS 506)

Increase/decrease sharpness

Increase/decrease sharpness

Cont/Bright

Adjust image contrast

Adjust image brightness

Color/Tint

Adjust image color

Adjust image tint

Adjusting an Image

Transition Effects

LISTED
1T23
I.T.E.

US

®

N15779

Selecting a wipe, PIP, or title effect (RCP with SGS or ISS 506 support only)
1
. Press and hold the Wipe button.
2. SGS: While holding the Wipe button, rotate the Adjust knob until the desired wipe or the title effect
number appears in the LCD window.

ISS 506: While holding down the Wipe button, repeatedly press the Dissolve button to cycle through the

menu options and select the display mode:

Wipe, PIP, or Title.

3. ISS 506 only: Select a wipe or PIP sub-effect, or set the intensity level at which the preview image will
become transparent in Title mode:

To select a Wipe or PIP sub-effect: With the desired function (Wipe or Pip) displayed in the LCD

window, continue to hold down the Wipe button while rotating the Adjust knob to the number of the
desired sub-effect (02–25 for Wipe mode; 01–25 for PIP mode — 01 selects dissolve). (The label on
the RCP front panel lists the sub-effect numbers.) Release the Wipe button.

To select the Title level: When Title is displayed, release the Wipe button and rotate the Adjust knob

to the desired level (000-255), while the Wipe button remains lit.
4. If appropriate, set the duration of the selected wipe or PIP sub-effect as follows:

a. Press and release the Wipe button.

b. While the Wipe button remains lit, rotate the Adjust knob to select the number of seconds the transition

will last.
5. Press the Take button to implement the effect on the selected preview input.

Adjusting image/window size and centering in PIP mode (ISS 506 only)
1
. Press the Size or Center (positioning) button repeatedly to toggle between image and window adjustment.
2. Rotate the H and/or V knob to select the size or position of the window or image.

N Image adjustments can be made to the preview input only. If PIP/Title effects are active, no

adjustment is possible.

Extron

USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517 FAX

Extron

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797 FAX

Extron

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664 FAX

Extron

Japan

+81.3.3511.7655

+81.3.3511.7656 FAX

Extron

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566 FAX

Extron

Dubai

+971.4.2991800

+971.4.2991880 FAX

Button

H adjustment knob

V adjustment knob

To adjust the preview image, press and release the
appropriate control button. The selected button lights.
Make adjustments with the H and V adjustment knobs.

Nothing happens if there is no second brief press.

Mode 1 – Holding the Reset button until the LCD display shows

Reset Mode 1 (3 seconds), followed by a brief press (<1 second),

stops all events. The LCD screen displays

Unit reset when reset

is done.
Mode 2 – Holding the Reset button until the LCD display shows

Reset Mode 2 (5 seconds), followed by a brief press (<1 second),

erases all user flash memory, resets ports to defaults, and reboots

the unit. The LCD screen displays

Unit reset when reset is done.

Mode 3 – Holding the Reset button until the LCD display shows

Reset Mode 3 (10 seconds), followed by a brief press (<1 second),

resets the unit to factory defaults. The LCD screen displays

Unit reset when reset is done.

Setting up the IP Addresses

Choosing an Effect

Center

Move image horizontally

Move image vertically

Size

Adjust image width

Adjust image height

Detail

Select horizontal filter

Select vertical filter

Cont/Bright

Adjust image contrast

Adjust image brightness

Color/Tint

Adjust image color

Adjust image tint

The following transition effects are available:
Dissolve – Causes the program input to fade out while the preview input is fading in. The dissolve duration
is adjustable from 0.2 to 5.0 seconds, using the

Adjust knob.

Wipe (SGS only) – Causes the preview image to appear to unroll over the program image. A variety of

wipes are available (21), including Standard, Curtain, Plus, and Square

(see the User's Manual for complete descriptions). The wipe duration is

adjustable from 0.2 to 5.0 seconds, using the

Adjust knob. Wipes are

selected by holding the

Wipe button and rotating the Adjust knob.

Cut – Seamlessly replaces the program image with the preview image.

33-873-01

Rev.

C

03 05

Extron Electronics, USA
1230 South Lewis Street

Anaheim, CA 92805

USA

714.491.1500

Fax 714.491.1517

Extron Electronics, Europe
Beeldschermweg 6C

3821 AH Amersfoort

The Netherlands

+31.33.453.4040

Fax +31.33.453.4050

Extron Electronics, Asia
135 Joo Seng Road, #04-01

PM Industrial Building

Singapore 368363

+65.6383.4400

Fax +65.6383.4664

Extron Electronics, Japan
Kyodo Building

16 Ichibancho

Chiyoda-ku, Tokyo 102-0082, Japan

+81.3.3511.7655

Fax +81.3.3511.7656

www.extron.com

Making a Transition

1. Select the desired Preview (input), and press the preview input select button to display the preview image on
the preview monitor.
2. Make adjustments (centering, size, detail, contrast/brightness, color/tint) to the preview image, if necessary
(see Adjusting an Image).
3. Select the duration of the dissolve or wipe by pressing the appropriate button (Dissolve or Wipe) and using
the

Adjust knob until the duration desired setting is displayed on the LCD screen.

4. If you selected a Wipe transition, choose the desired wipe effect by pressing and holding the Wipe button
while turning the

Adjust knob. Turn the knob until the wipe effect you want appears on the LCD screen.

5. When you want the transition to occur, press the appropriate button (Wipe or Dissolve) for the effect you
want, then press the

Take button or move the T-bar up or down to make the transition.

Alternatives
1.
For an instant switch, press the Cut button.
2. To freeze the output display, press the Program button, then the Freeze button.
3. T o cause a black screen to be displayed, press the Program button, then the Black button.

Adjusting an Image

The RCP 2000 ships with default client (RCP) and server (ISS or SGS) IP addresses already set. If you want
to change the default addresses, follow these steps:
1. Slide the T-bar handle to the top or bottom of its slot.
2. Press the Wipe, Dissolve, Cut, and Take buttons simultaneously until the LCD screen changes to show
the unit's MAC address (xx-xx-xx-xx-xx-xx).
3. Press the Take button. The Take, Cont/Bright, Size, and Center buttons light, and the Color/Tint button
blinks. The client (RCP) IP address (IP) is displayed on the LCD screen.
4. Press the appropriate picture control button, then turn the H Adjust knob to change each block of the
RCP’s IP address, as follows:
– Press the

Color/Tint button, then change the first block of the IP address.

– Press the

Cont/Bright button, then change the second block of the IP address.

– Press the

Size button, then change the third block of the IP address.

– Press the

Center button, then change the fourth block of the IP address.

5. Press the Take button again. The server (ISS or SGS) IP address (SI) is displayed on the LCD screen.
Repeat step

4 to change the server IP address.

6. Press the Take button again. The Subnet Mask (SM) is displayed on the LCD screen. Repeat step 4
to change the Subnet Mask.
7. Press the Take button again. The Gateway (GM) address is displayed on the LCD screen. Repeat step 4
to change the Gateway address.
8. Press the Detail button to exit and save the changes when all changes have been made.

Reset Modes

RCP 2000 Remote Control Panel

Old Label (Rev C)

New Label (Rev D)

Front of RC

P

Front of RC

P

Extron Electronics, Anaheim, CA

+800.633.987 +1.714.491.1500
www.extron.com

H

V

WIPE

DISOLVE

ADJUST

RCP 2000

Affix Sub-effects label here.

DETAIL

01 = Dissolve (PIP only) 10 = Soft Square In 18 = Hard Center In
02 = Soft Right

11 = Soft Square Out 19 = Hard Center Out

03 = Soft Left

12 = Soft Plus In

20 = Hard Curtain In

04 = Soft Up

13 = Soft Plus Out

21 = Hard Curtain Out

05 = Soft Down

14 = Hard Right

22 = Hard Square In

06 = Soft Center In

15 = Hard Left

23 = Hard Square Out

07 = Soft Center Out

16 = Hard Up

24 = Hard Plus In

08 = Soft Curtain In

17 = Hard Down

25 = Hard Plus Out

09 = Soft Curtain Out

Wipe and PIP Sub-effects

33-1635-01 Rev

A

03 08

LOGO1

/BLACK

LOGO2

/BLACK

LOGO 1
/BLACK

LOGO 2
/BLACK

AUTO

IMAGE

LOGO 1
/BLACK

LOGO 2
/BLACK

9

PROGRAM

PREVIEW

10

9 10

11

11

12

12

Before

After

8

8

8

8