Extron Electronics MLC 206 Replacing Quick Start User Manual

Quick start — replacing mlc 206 firmware, Firmware replacement, Step 1

Advertising
background image

Quick Start — Replacing MLC 206 Firmware

Firmware Replacement

In some cases the MLC’s firmware may require replacement with an updated version. We recommend
that you send the unit in to Extron for service and updates.

CAUTION

Changes to firmware must be performed by authorized service personnel only.

Follow these steps to replace firmware in the MLC 206.

Step 1

Disconnect the power supply from the power source.

To prevent electric shock, always unplug the MLC from the power source before opening the
enclosure.

Step 2

Remove the MLC from the wall or furniture.

Step 3

Remove the MLC’s rear cover.

A.

Remove the five Philips head screws that fasten the rear cover to the main part of the enclosure.

B.

If applicable, disconnect the host computer’s RS-232 cable from the MLC’s 9-pin Control connector.

C.

Remove the two hex standoffs, which are on either side of the 9-pin Control connector.

D.

Lift the cover straight off the MLC.

Remove five screws.

Remove two hex screw connectors.

A

B

C

D

E

A

B

C

IR

Displa

y/Sour

ce Contr

ol

Extr

on Switc

her Contr

ol

Rela

ys

IR

/RCM

RS-232

D

E

A

B

C

A

B

D

1A

1B

2A

2B

3A

3B

1

2

3

4

5

6

Tall

y Out

MLS

/Power

33-644-01 A

07 01

Pr
inted in the

USA

Lift cover straight up.

CAUTION

Do not touch any other electronic components inside the MLC. Doing so could damage the
MLC. Electrostatic discharge (ESD) can damage IC chips even though you cannot feel it. You
must be electrically grounded before proceeding with firmware replacement. A grounding wrist
strap is recommended.

Step 4

Locate the main controller firmware chip on the circuit board at U6, and note which end has the
direction indicator notch, as shown in the following illustrations.

Notch

68-718-01, Rev. A

Printed in the USA

08 02