7. Minimum setting adjustment of the DRDA (DCDR) burner

with discrete adjustment and LED visualisation:

• To adjust the outer ring, turn the knob anti-clockwise

to the minimum power position.

• To adjust the minimum power setting of the inner ring,

turn the knob clockwise to the minimum power position.

• Remove the knob and intervene on the adjustment

screw located near the tap pin.

! If the appliance is connected to liquid gas, the regulation

screw must be fastened as tightly as possible.

! Once this procedure is finished, replace the old rating

sticker with one indicating the new type of gas used. Stickers

are available from any of our Service Centres.

! Should the gas pressure used be different (or vary slightly)

from the recommended pressure, a suitable pressure

regulator must be fitted to the inlet pipe (in order to comply

with current national regulations).

Electrical

connections

DATA PLATE

see data plate

This appliance conforms to the following

European Economic Community directives:

- 2006/95/EEC dated 12/12/06 (Low

Voltage) and subsequent amendments

- 2004/108/EEC dated 15/12/04

(Electromagnetic Compatibility) and

subsequent amendments

- 93/68/EEC dated 22/07/93 and

subsequent amendments.

- 2009/142/EEC dated 30/11/09 (Gas) and

subsequent amendments.

- 2002/96/EC and subsequent

amendments.

Table 1 Liquid Gas Natural Gas

Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow*

power power 1/100 1/100 (g/h) power 1/100 (l/h)

kW kW kW

(p.c.s.*) (p.c.s.*) (p.c.s.*)

(mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)

Supply pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20

35

37

25

45

20

17

25

Fast (R)

Reduced Fast (RR)

Semi Fast (S)

Auxiliary (A)

Triple Crown (TC)

100

100

75

55

130

0.70

0.70

0.40

0.40

1.50

3.00

2.60

1.65

1.00

3.30

39

39

28

28

61

86

80

64

50

65x2

218

189

120

73

240

214

186

118

71

236

3.00

2.60

1.65

1.00

3.60

132 (H)

122 (H)

96 (Y)

79 (6)

103x2

286

248

157

95

343

Double flame

(DCDR internal) (1)

30

0,30

0,90

27

44

65

64

0,90

74

86

Double

flame (1)

(DCDR

internal)

(DCDR

external
2 nozzle)

130

1,50

3,60

27

44

262

257

3,60

74

343

55

60x2

100x 2

Burner and nozzle specifications (for 60 cm and 65 cm versions only)

(1) For single-control DRDA (DCDR) burner only

(2) For dual-control DRDA (DCDR) burner only

*

At 15°C and 1013 mbar - dry gas

**

Propane P.C.S. = 50.37 MJ/Kg

***

Butane P.C.S. = 49.47 MJ/Kg

Natural P.C.S. = 37.78 MJ/m³

Double Flame

(DCDR Internal) (2)

Double Flame

(DCDR External)

2 nozzle (2)

30

130

0.40

1.50

0.90

3.60

27

55

44

67x2

65

262

64

257

0.90

3.60

74

100x2

86

343