Extron Electronics SW6 VGA A Switcher Setup Guide User Manual

Setup guide — sw6 vga a switcher, Setup guide — sw6 vga a switcher, cont’d, Installation

Advertising
background image

Setup Guide — SW6 VGA A Switcher

This card provides quick start instructions for an experienced

installer to set up and operate the Extron

®

SW6 VGA A

switcher with audio.

Installation

Step 1 — Mounting

Turn off or disconnect all equipment power sources

and mount the switcher as required.

50/60 Hz

100-240V 0.3A

3

1

2

Step 2 — Connections

a

AC power connector — Plug a standard IEC power cord between this connector

and a 100 VAC to 240 VAC, 50-60 Hz power source.

b

Video Input connectors — Connect up to six RGBHV computer video (VGA–QXGA)

inputs to these 15-pin HD connectors.

N

The switcher can also accept RGBS, RGsB, RsGsBs, and HDTV component video.

c

Video Output connectors — Connect an RGBHV (VGA-QXGA) video display to

this female 15-pin HD connector.

L

1

R

L

2

R

L

3

R

L

4

R

L

5

R

L

6

R

L

1

R

6

5

4

d

Audio Input connectors — Connect balanced or unbalanced audio inputs to these

3.5 mm, 5-pole captive screw connectors. Wire the connectors as shown below.

L

R

Unbalanced Stereo Input

Balanced Stereo Input

(high impedance)

(high impedance)

Do not tin the wires!

L

R

Tip

Sleeve

Tip

Sleeve

Tip

Ring

Sleeve (s)

Tip

Ring

Balanced Stereo Output

Unbalanced Stereo Output

Tip

Ring

Sleeve (s)

Tip

Ring

Sleeve(s)

L

R

L

R

Tip

Tip

NO GROUND HERE.

NO GROUND HERE.

For unbalanced audio output, connect the sleeve(s) to the ground contact.

DO NOT connect the sleeve(s) to the negative (-) contacts).

CAUTION

e

Audio Output connector — Connect a balanced or unbalanced stereo or mono

audio device to this 3.5 mm, 5-pole captive screw connector. Wire the connectors as

shown above.

Setup Guide — SW6 VGA A Switcher, cont’d

68-377-50

Rev. A 01 10

f

Remote connector — Connect an RS-232 OR a contact

closure device, such as a KP 6 Keypad Remote Control.

RS-232 communications protocols:
• 9600 baud

• 8 data bits

• 1 stop bit, no parity

• no flow control

For contact closure control, short the pin for the desired

input to pin 5 to select that device. To force an input

to be always selected, leave the short in place.

N

For contact closure control, auto switch mode must be off.

See “Switch mode“ below.

Contact closure control

overrides front panel input selections.

Operation

Select an input

N

Switcher must be in normal (manual) mode.

Press and release an input button to select that input. That Input LED lights.

Switch mode

In auto switch mode, the switcher selects the highest-numbered input with sync signals

present. Toggle auto switch mode on and off as follows:

1.

Press and hold the Mode (Input 1) button.

2.

Press and release either the Auto (Input 3) or Normal (Input 2) button. The Auto Switch

Mode Active LED lights or goes out.

3.

Release the Mode button.

Set an input audio level in the range of -15 dB to +9 dB

1.

Press and hold the Audio Conf/Save button until the Audio Conf/Save LED begins to

blink, then release the button. See the SW6 VGA A User’s Manual to read the audio level

display.

2.

Press and release the

>

and

<

buttons to increase and decrease the audio level by 1 dB or

press and hold the button to increase or decrease the level by 3 dB per second.

3.

Press and hold the Audio Conf/Save button until the Audio Conf/Save LED turns off to

save the gain value in memory and exit the audio display and adjustment mode.

Resetting all audio levels

To reset the audio level to 0 dB for all inputs, press and hold the Audio Configuration/
Save button. The Audio Configuration/Save LED begins to blink after approximately 1

second. Continue to hold the button for approximately 10 seconds until the LED turns off.

All input audio levels are reset to 0 dB.

Extron

USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517 FAX

Extron

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797 FAX

Extron

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664 FAX

Extron

Japan

+81.3.3511.7655

+81.3.3511.7656 FAX

Extron

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566 FAX

Extron

Middle East

+971.4.2991800

+971.4.2991880 FAX

© 2010 Extron Electronics. All rights reserved.

REMOTE

PIN RS-232

Contact
Closure Function

1

In #1

Input #1

Input #2

Input #3
Input #4
Input #5
Input #6

2

TX

Transmit data

3

RX

Receive data

4

In #2

5

Gnd

Gnd

Ground

6

In #3

7

In #4

8

In #5

9

In #6

Advertising