En 13 maintenance – Imetec PIUMA NEXT CYCLONIC 1300W PARQUET User Manual
Page 21
EN
13
MAINTENANCE
IMPORTANT!
Turn the appliance off and unplug it from the socket before opening the
dust collection system!
Make sure all cleaned parts are completely dry before reusing the
appliance!
CLEANING THE APPLIANCE
When necessary, clean the appliance with a damp cloth.
IMPORTANT!
DO NOT USE SOLVENTS OR OTHER AGGRESSIVE OR ABRASIVE
DETERGENTS. THIS CAN DAMAGE THE SURFACE.
CLEANING THE COMBINATION BRUSH (6)
With the motor on and the bristles in position (A)
(extended bristles), rub the lower
part of the brush with your hand to remove dust and fluff that will be directly vacuumed.
CLEANING THE DUST COLLECTION SYSTEM (8):
IMPORTANT! Empty the dust compartment (8A) and clean the filtering
system (8A, 8B, 8C) after every use.
Do not fill the compartment above the MAX level (8D).
Clean the dust collection system following the instructions below and paying attention to
the figures in the illustrative guide.
Cleaning the dust container (8A)
• Pull the dust compartment lever (9) [FIG. F1] and remove the dust collection system (8)
from the appliance [FIG. F2].
• Remove the filtering system (8B+8C) [FIG F3].
• Empty the dust compartment (8A) [FIG. F4].
• When necessary, rinse the dust compartment (8A) and let it dry completely.
• Reinstall the filtering system (8B+8C) in the dust compartment (8A) [FIG F3].
• Fit the dust collection system (8), inserting the lower part into its guide [FIG. F2].
• Press the upper part of the dust compartment cover until it snaps into place, which
indicates that the dust compartment lever is properly locked (9).
NOTE:
A safety device prevents closing the dust compartment (8A) if the filtering system
(8B+8C) is missing or not installed properly.
MI000889_IT-EN.indd 13