Vi. troubleshooting guide – Spencer FastVac Vacuum Cleaning Systems User Manual
Page 7
7
PROBLEM
Possible Cause
Corrective Action
MOTOR DOES NOT TURN
AND THERE IS…
HUMMING SOUND
– One phase of power line disconnected
Connect power leads properly
– One phase of stator line open
Contact Spencer
– Bearing(s) defective
Change defective bearing(s)
– Impeller jammed by foreign material
Clean impeller
– Impeller jammed against casing or side cover
Adjust gap
– Rubbing of rotor core and stator core
Contact Spencer
– Capacitor open (single-phase models)
Change capacitor
NO SOUND
– Two phases of power line disconnected
Connect power leads properly
– Two phases of stator winding open
Contact Spencer
– Faulty switch connection
Change switch
– Fuse blown
Change fuse
MOTOR TURNS, BUT…
FUSE BLOWS
– Fuse capacity insufficient, wiring fault
Inspect wiring
– Short circuit
Repair
– Terminals shorted
Improve insulation and check connections
– Excessive load
Increase airflow
OVERHEATS OR OVERLOAD
RELAY ACTIVATES
– Power source unbalance; possible
Check voltage; phases must be
VOLTAGE DROP
balanced within 5% and voltage
must be within 10% of rated
– Operating in single-phase condition
Check connections
– Excessive friction due to defective bearings
Replace bearings
– Impeller contaminated by foreign material
Clean impeller
– Impeller rubbing against casing or side cover
Adjust gap
– Operation at less than minimum rated flow
Increase airflow (check relief valve)
– Incorrect vacuum relief
Adjust bleed
MAKES ABNORMAL SOUND
– Impeller rubbing against casing or side cover
Adjust gap
– Impeller rubbed by foreign material
Clean impeller
– Bearing(s) defective
Replace bearings
– There is a leak or air passages are clogged
Repair or clean
– Loose cap screw
Tighten screw
LOW SYSTEM VACUUM
– Clogged filter
Clean filter
– Leak in tubing system
Locate and remove leak
– Leak in dirt can
Clean or replace gasket
– Too many operators on line
Reduce the number of users
DIRT COMING OUT
– Filter is damaged or improperly installed
Replace or reinstall filter
OF EXHAUST
– Material vacuumed is extremely fine
Consult Spencer
SYSTEM MAKES
– Leak at a machine joint
Check dirt can and top cover
HIGH-PITCHED SQUEAL
VI. Troubleshooting Guide