XIII. Trouble Shooting Guide -

Separators

Trouble

Probable Cause

Corrective Action

Centrifugal Separators

Vacuum Producer Motor

– Leaks.

Check access doors for tightness. Check dirt

Overload

can or discharge valve sealing. Check for
holes worn in separator (when handling abrasive
materials.

Low Vacuum in System

– Leaks.

See above.

– Screen Clogged.

Clean screen (access through clean-out door
in side of Separator).

Majority of Material

– Leaks.

See above. A small leak will greatly affect

Not Being Collected

separation efficiency.

Tubular Bag Separators

Vacuum Producer Motor

– Leaks.

See above.

Overload

Low Vacuum in System

– Leaks.

See above.

– System Overload

See Vacuum Producer Trouble Shooting Guide

– Bags Clogged

Shake bags at more frequent intervals (only
shake bags when system is not running).
Air leaks blowing debris into filter eliminate leaks.

Dirt Passing Through

– Loose bag.

Check bags and re-install per instructions.

Separator and
Clogging Vacuum

– Holes in bags.

Carefully examine bags for holes and replace

Producer or Being

defective bags.

Exhausted

– Incorrect filter material.

Contact factory.

.

Advertising