PROBLEM

CAUSE

SOLUTION

Unit will not run. 1. No power to unit.

1. Plug unit in. Check circuit breaker.

2. Switch not on.

2. Place in “ON” position.

3. Switch is faulty.

3. Replace switch.

4. Faulty/broken cord or

4. Perform continuity check, using

motor wire.

volt/amp meter. Repair/replace

faulty broken wire.

Unit runs but air 1. Unit has been severely jolted

1. Remove motor and replace

mover makes

causing blower wheel to rub

damaged motor or motor mounts,

loud scraping

against housing.

as needed.

noise.

2. Unit has been severely jolted

2. Replace blower wheel or damaged

causing housing to deform.

housing.

Unit runs but

1. Severe jolt has bent motor

1. Remove and replace motor.

vibrates

shaft, causing unit to be out of

excessively.

balance.

2. Blower wheel blade damaged.

2. Replace blower wheel if necessary.

3. Dirt built up on one side of

3. Clean blower wheel blades.

air mover blower wheel.

Unit runs but

1. Blower wheel is jammed

1. Remove motor and replace

blower wheel

against housing.

damaged motor mounts. Replace

does not turn.

blower wheel if necessary.

2. Capacitor wire has broken/

2. Repair/replace wires/motor as

come loose, capacitor has

necessary.

failed.

3. Housing has been damaged

3. Replace housing/unit as necessary.

such that it presses on blower

wheel.

Unit runs briefly, 1. Motor bearings are failing or

1. Replace motor.

then shuts off

motor has developed an

on overload.

internal electrical fault.

2. Intake grille and /or exhaust

2. Remove obstruction.

grille is obstructed.

SP6769-1 PROTEAM ProBlitz 8/15/11 9:19 AM Page 10