Electrical connection

• Ground the appliance according to safety precautions.
• Make sure that the rated voltage and type of power on

the rating plate agree with the voltage and the power of

the local power supply.

• This appliance is supplied with a mains cable. It has to

be supplied with a correct plug, able to support the

load marked on the rating plate. The plug has to be fit-

ted in a correct socket.

• Any electrical component must be installed or replaced

by the Service Force Centre technician or qualified

service personnel.

• Always use a correctly installed shockproof socket.
• Make sure that there is an access to the mains plug af-

ter installation.

• Do not pull the mains cable to disconnect the appli-

ance. Always pull the mains plug.

• The appliance must not be connected with an extension

cable, an adapter or a multiple connection (risk of fire).

Check that the ground connection is in conformity with

the standard and regulations force.

• The power cable must be placed in such a way that it

does not touch any hot part.

• Connect the appliance to the mains with a device that

lets to disconnect the appliance from the mains at all

poles with a contact opening width of minimum 3 mm,

eg. automatic line protecting cut-out, earth leakage

trips or fuse.

• None of a parts of the connection cable can not get a

temperature 90 °C. The blue neutral cable must be

connected to the terminal block label with "N". The

brown (or black) phase cable (fitted in the terminal

block contact marked with "L") must always be connec-

ted to the live phase.

Replacement of the connection cable

To replace the connection cable use only H05V2V2-F T90

or equivalent type. Make sure that the cable section is ap-

plicable to the voltage and the working temperature. The

yellow/green earth wire must be approximately 2 cm lon-

ger than the brown (or black) phase wire.

Assembly

55 mm

30 mm

min. 650 mm

490 mm

min. 100 mm

270 mm

40-50 mm

min. 600 mm

B

A

A) seal to remove
B) supplied brackets

Possibilities for insertion

Kitchen unit with door
The panel installed below the hob must be easy to remove

and let an easy access in case a technical assistance inter-

vention is necessary.

min 20 mm

(max 150 mm)

30 mm

60 mm

b

a

a) Removable panel
b) Space for connections