Cla-Val 580 Series User Manual

Wafer & globe silent check valves, Series installation / operation / maintenance, Operation

Advertising
background image

WAFER & GLOBE SILENT CHECK VALVES

580 & 581

SERIES

INSTALLATION / OPERATION / MAINTENANCE

Note 1: flanged gasket
must bridge this joint
for pressure seal

Installed with name plate here

6

2

3

4

5

1

OPERATION:

Cla-Val Silent Check Valves operate automatically, to open...
when pump flow starts and close silently ...when pump flow
stops.

INSTALLATION:

Silent Check Valves, Wafer and Globe style must be
installed between flat faced iron or steel flanges per ANSI
B16.5 or Awwa 207, utilizing a full faced gasket to bridge the
joint between the seat O.D. (2) and the body (1) flange face.
In this manner a pressure seal at this joint is made (see
Note 1). Install the valve so that the nameplate data is plain-
ly read and the flow arrow points in the flow direction.

Detail

1
2
3

4
5
6

Description

Body
Seat*
Disc*

Spring*
Bushing*
Screw*

Material

Cast Iron
Bronze or SS
Bronze or SS
(Optional Buna-N

®

)

Stainless Steel
Bronze
Stainless Steel
(3” & larger valves)

* Recommended Spare Part Kit

Note 2: All size 2” and 2 1/2” valves have
threaded seats in liev of screws

FLOW OPEN

See
Note 2

SERIES 580

WAFER STYLE CHECK VALVE

2" THRU 10"

1

2

6

3

4

5

Series 581

Globe Style
Check Valve
2” thru 42”

MAINTENANCE:

Cla-Val Silent Check Valves are ruggedly designed for years of trouble-free
service. Therefore, regular maintenance is not required. However, during
initial start-up period the following problems may surface (due to mis-application)
that can be easily resolved:

A. No Flow thru Valve:

1. Observe that the flow arrow name plate, on the

valve body, is pointing in the direction of flow.

2. Check that the down stream shut-off valve is full open.

B. Valve Chatters:

1. Confirm that the flow velocity is a minimum 3’/Sec.
2. Check that there is a minimum of 3 diameters of

straight pipe installed up stream of the silent check valve.

C. Valve Leakage:

1. Confirm a full face gasket is installed per Note 1.

A

MAXIMUM ALLOWABLE INSIDE

DIAMETER OF FLANGE

(SEE NOTE NO. 1 )

VALVE SEAT

VALVE DISC

VALVE BODY

ANSI B16.5 COMPANION
FLANGE WITH FLAT FACE

MAXIMUM ALLOWABLE INSIDE

DIAMETER OF FLANGE

(SEE NOTE No. 1)

VALVE

SIZE

A

VALVE

SIZE

A

2

1

⁄2

2.940

14

14.140

3

3.570

16

16.160

4

4.570

18

18.180

5

5.660

20

20.200

6

6.720

24

24.250

8

8.720

30

30.250

10

10.880

36

36.250

12

12.880

42

42.250

STANDARD RING GASKET DIMENSIONS (SEE NOTE No. 2)

Valve

Size

I.D. For
125 Lb.

and

250 Lb.

Gasket

O.D. for

125 Lb.

Gasket

O.D. for

250 Lb.

Gasket

Valve

Size

I.D. For
125 Lb.

and

250 Lb.

Gasket

O.D. for

125 Lb.

Gasket

O.D. for

250 Lb.

Gasket

2

1

2

2.875

4.875

5.125

14

14.000

17.750

19.125

3

3.50

5.375

5.875

16

16.000

20.250

21.250

4

4,50

6.875

7.125

18

18.00

21.625

23.500

5

5.562

7.750

8.500

20

20.00

23.875

25.750

6

6.625

8.75

9.875

24

24.000

28.250

30.500

8

8.625

11.000

12.125

30

30.000

34.750

37.500

10

10.750

13.375

14.250

36

36.000

41.250

44.000

12

12.750

16.125

16.625

42

42.000

48.000

50.750

Note No. 1 - The mating companion flange I.D. must overlap the Valve seat.

This is required to achieve a seal between the seat O.D. and
The Body I.D. Interface area.

Silent Check Valve - Flanged or Wafer Style

(Flanged Style Shown)

Ring or Full Faxe Gasket