Liberty Pumps Ascent II User Manual

Page 15

Advertising
background image

©Copyright 2013 Liberty Pumps Inc. All rights reserved.

15

Toilet flushes normally but does not evacuate or

drain from the bowl.

Macerator starts to run and sounds normal

(running) then stops after 5-10 min.

Restarts after 30 to 60 min.

Alarm is activated

The macerator is unable to evacuate its holding tank and is cycling on thermal overload

Damaged Impeller

Replace impeller

Check valve stuck closed

Confirm the check valve is functioning properly; if not it

must be repaired or replaced.

Internal hose is damaged or

disconnected

Confirm the internal hose is functioning properly; if not it

must be replaced.

If the macerator was installed with a

ball valve in the discharge line, is the

valve open?

Open ball valve

Air lock

The volute has a passage way to allow trapped air to

escape, this passage way must be cleaned of

obstruction

Volute inlet plugged

The volute’s inlet, located on the bottom of the pump

cartridge, requires cleaning.

Toilet Flushes normally but macerator does not

turn on or just hums

Green light is on steady (solid)

The macerator is jammed

The cutter or impeller are jammed

preventing the motor from turning

Clear the cutter or impeller of blockage

Internal motor problem

The pump cartridge must be replaced

Waste build up in the toilet bowl

The toilet has an inadequate flush volume, possible blockage of the strainer basket, or

improper venting.

Inadequate water level in the reservoir

tank

Check and / or adjust the water fill mechanism so that

the water level matches the reference line in the tank

Strainer basket requires cleaning

Clear debris from the strainer basket

Unit is not vented correctly

Unit must be vented properly to open air to allow water

to enter the macerator tank. Confirm vent is clear.

DO NOT USE A QUICK VENT